CA3028A, CA3028B, CA3053
Operating Conditions
Temperature Range . . . . . . . . . . . . . . . . . . . . . . . . . -55
o
C to 125
o
C
Thermal Information
Thermal Resistance (Typical, Note 1)
θ
JA
(
o
C/W)
θ
JC
(
o
C/W)
Metal Can Package . . . . . . . . . . . . . . .
225
140
PDIP Package . . . . . . . . . . . . . . . . . . .
155
N/A
SOIC Package . . . . . . . . . . . . . . . . . . .
185
N/A
Maximum Junction Temperature (Metal Can Package) . . . . . . . 175
o
C
Maximum Junction Temperature (Plastic Package) . . . . . . . . 150
o
C
Maximum Storage Temperature Range . . . . . . . . . .-65
o
C to 150
o
C
Maximum Lead Temperature (Soldering 10s) . . . . . . . . . . . . 300
o
C
(SOIC - Lead Tips Only)
CAUTION: Stresses above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. This is a stress only rating and operation
of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied.
NOTE:
1.
θ
JA
is measured with the component mounted on an evaluation PC board in free air.
Absolute Maximum Voltage Ratings
T
A
= 25
o
C
The following chart gives the range of voltages which can be applied to the terminals listed
horizontally with respect to the terminals listed vertically. For example, the voltage range of the
horizontal Terminal 4 with respect to Terminal 2 is -1V to +5V.
TERM
NO.
1
2
3
(Note 2)
4
5
6
7
8
+10 to 0
1
2
0 to -15
(Note 4)
3
0 to -15
(Note 4)
+5 to -11
4
0 to -15
(Note 4)
+5 to -1
5
+5 to -5
+15 to 0
(Note 6)
+15 to 0
(Note 6)
+15 to 0
(Note 6)
6
Note 3
Note 3
+30 to 0
(Note 7)
Note 3
+20 to 0
(Note 5)
7
Note 3
+15 to 0
(Note 6)
+15 to 0
(Note 6)
Note 3
Note 3
Note 3
8
+20 to 0
(Note 5)
Note 3
Absolute Maximum
Current Ratings
TERM
NO.
1
2
I
IN
mA
0.6
4
0.1
20
0.6
20
4
20
I
OUT
mA
0.1
0.1
23
0.1
0.1
0.1
0.1
0.1
+30 to 0
(Note 7)
Note 3
3
4
Note 3
5
Note 3
6
Note 3
7
8
NOTES:
2. Terminal No. 3 is connected to the substrate and case.
3. Voltages are not normally applied between these terminals. Voltages appearing between these
terminals will be safe, if the specified voltage limits between all other terminals are not exceeded.
4. Limit is -12V for CA3053.
5. Limit is +15V for CA3053.
6. Limit is +12V for CA3053.
7. Limit is +24V for CA3028A and +18V for CA3053.
Electrical Specifications
PARAMETER
DC CHARACTERISTICS
Input Offset Voltage
(Figures 1, 14)
Input Offset Current
(Figures 2, 14)
Input Bias Current
(Figures 2, 3, 15, 16)
V
IO
I
IO
I
I
T
A
= 25
o
C
CA3028A
CA3028B
MAX MIN
-
-
-
-
70
106
-
-
-
-
-
-
-
-
-
-
TYP
0.98
0.89
0.56
1.06
16.6
36
-
-
MAX MIN
5.0
5.0
5.0
6.0
40
80
-
-
-
-
-
-
-
-
-
-
CA3053
TYP
-
-
-
-
-
-
29
36
MAX UNIT
-
-
-
-
-
-
85
125
mV
mV
µA
µA
µA
µA
µA
µA
SYMBOL
TEST CONDITIONS
V
CC
= 6V, V
EE
= -6V
V
CC
= 12V, V
EE
= -12V
V
CC
= 6V, V
EE
= -6V
V
CC
= 12V, V
EE
= -12V
V
CC
= 6V, V
EE
= -6V
V
CC
= 12V, V
EE
= -12V
V
CC
= 9V
V
CC
= 12V
MIN
-
-
-
-
-
-
-
TYP
-
-
-
-
16.6
36
-
-
7-7