www.hamlin.com
59020 Mini Firecracker Features and Benefits
Actuator
Features
•
2 part magnetically operated
proximity sensor
•
Normally open contact
•
Customer defined sensitivity
•
Choice of cable length and
connector
Benefits
•
Quick and easy to install
•
No standby power requirement
•
Operates through non-ferrous
materials such as wood, plastic or
aluminium
•
Hermetically sealed, magnetically
operated contacts continue to
operate long after optical and other
technologies fail due to
contamination
Applications
•
•
•
•
Position and limit sensing
Security
Level sensing
Linear actuators
Sensor
DIMENSIONS (in) mm
A
Max
57020
59020
(.201) 5,10
(.201) 5,10
B
Max
(.600) 15,24
(.600) 15,24
C
NOM.
-
Table 3 ± (.393) 10,00
CUSTOMER OPTIONS - Switching Specifications
TABLE 1
Contact Type
Switch Type
Power
Voltage
Current
Resistance
Capacitance
Temperature
Time
Shock
Vibration
Switching
Breakdown
Switching
Carry
Contact, Initial
Insulation
Contact
Operating
Storage
Operate
Release
11ms 1⁄2 sine
50-2000 Hz
Watt - max.
Vdc - max.
Vdc - min.
A - max.
A - max.
Ω
- max.
Ω
- min.
pF - typ.
°C
°C
ms - max.
ms - max.
G - max.
G - max.
Form A
Normally
Open
1
10
170
175
0.5
0.5
0.2
10
10
0.2
-40 to +105
-65 to +105
1.0
1.0
100
30
CUSTOMER OPTIONS - Sensitivity, Cable Length and Termination Specification
TABLE 2
Sensitivity Options:-
Activate Distances are approximate
using Hamlin 57020 actuator
as illustrated.
Switch AT before modification
Select Option
Switch
Type
S
Pull In
AT
Range
6-10
Activate
Distance
d
(in) mm
(.236)
6,0
Pull In
AT
Range
10-15
T
Activate
Distance
d
(in) mm
(.177)
4,5
Pull In
AT
Range
13-19
U
Activate
Distance
d
(in) mm
(.157)
4,0
01
02
03
1 Normally Open
04
05
TABLE 3
Cable Type:-
24 AWG 7/32 PVC 105
o
C
UL1430/UL1569
TABLE 4
Termination Options:-
SELECT
OPTION
DESCRIPTION
Standard Lengths
SELECT
OPTION
CABLE
LENGTH
A
B
C
D
E
Tinned leads
Crimped terminals
6.35mm fastons
AMP MTE 2.54mm pitch
JST XHP 2.5mm pitch
(in)
mm
(3,94) 100
(11,81) 300
(19,69) 500
(29,53) 750
(39,37) 1000
ORDERING INFORMATION
N.B. 57020 actuator sold separately
59020
59036
Table 1
Table 2
Table 2
3
Table 3
4
X
1
X
T
XX
X
Series 59020
Switch Type
Sensitivity
Cable Length
Termination
Hamlin USA
Hamlin UK
Hamlin Germany
Hamectrol France
ISSUE No: 4 DATE: 1/5/3
Tel:
Tel:
Tel:
Tel:
+1 920 648 3000
•
Fax: +1 920 648 3001
•
Email: sales.us@hamlin.com
+44 (0)1379 649700
•
Fax: +44 (0)1379 649702
•
Email: sales.uk@hamlin.com
+49 (0) 6181 953660
•
Fax: +49 (0) 6181 9536666
•
Email: sales.de@hamlin.com
+33 (0) 1 4687 0202
•
Fax: +33 (0) 1 4686 6786
•
Email: sales.fr@hamlin.com
21
DETAILS PROVIDED ON THIS DATA SHEET ARE PROVIDED FOR
INFORMATION PURPOSES ONLY AND SHOULD NOT BE RELIED
UPON AS BEING ACCURATE FOR ANY PARTICULAR PURPOSE.
Product performance may be affected by the application to which the
product is put. Upon request, HAMLIN will assist purchasers by
providing information specific to any particular application. HAMLIN
disclaims any and all liability whatsoever for any purchaser’s reliance
upon the information contained on this data sheet without further
consultation with authorised representatives of HAMLIN.