MODULE
Mini-spectrometer TG series
C9406GC, C9913GC, C9914GB
Integrating optical system, image sensor and circuit
Hamamatsu TG series mini-spectrometers are polychromators integrated with optical elements and an image sensor. Light to be measured is
guided into the entrance port of TG series through an optical fiber and the spectrum measured with the built-in image sensor is output from the
USB port to a PC for data acquisition. Non-cooled type and cooled type are provided. Non-cooled type is a palmtop-size unit and operates on
USB bus power. Cooled type allows accurate measurement with low noise by cooling the image sensor. Two models are available: C9913GC
(TG-cooled NIR-I) and C9914GB (TG-cooled NIR-II). The TG series comes with sample software, device driver and DLL that let you easily set
measurement conditions and acquire, save and graphically display the spectrum data.
Features
Applications
C9406GC (TG-NIR)
l
High throughput due to transmission grating made of quartz
l
Highly accurate optical characteristics
l
Water content measurement
l
G9406GC: No external power supply required
l
Optical communication component testing
1
(Uses USB bus power) *
l
Film thickness measurement
l
Low noise measurement (Cooled type)
C9913GC (TG-cooled NIR-I), C9914GB (TG-cooled NIR-II)
l
Compact design for easy assembly
l
Water content measurement
l
Wavelength conversion factor *
2
is recorded in internal
l
Component analysis in food, agriculture fields, etc.
memory
l
Process control for chemical products
*1: C9913GC, C9914GB: Each requires 5 V and 12 V
power supplies.
*2: A conversion factor for converting the image sensor
pixel number into a wavelength is recorded in the
module. A calculation factor for converting the A/D
converted count into the input light intensity is not pro-
vided.
n
Mini-spectrometer line-up
Type No.
Type
TM-UV/VIS-CCD
High sensitivity
TM-UV/VIS-CCD
High resolution
Spectral response range (nm)
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
Spectral resolution
Max.
(nm)
Image sensor
C10082CA
C10082CAH
6
200 to 800
1*
6
8
(λ=320 to 900 nm)
Back-thinned type
CCD image sensor
TM series
C10082MD
C10083CA
C10083CAH
TM-UV/VIS-MOS
Wide dynamic range
TM-VIS/NIR-CCD
High sensitivity
TM-VIS/NIR-CCD
CMOS linear
image sensor
High resolution
TM-VIS/NIR-MOS
320 to 1000
Back-thinned type
CCD image sensor
1*
(λ=320 to 900 nm)
TG series TG series
C10083MD
C9404CA
C9404CAH
C9404MC
C9405CA
C9405MC
C9406GC
C9913GC
C9914GB
Wide dynamic range
TG-UV-CCD
8
3
200 to 400
CMOS linear
image sensor
Back-thinned type
CCD image sensor
Back-thinned type
CCD image sensor
CMOS linear
image sensor
High sensitivity
TG-UV-CCD
High resolution
TG-UV-MOS
1*
3
Wide dynamic range
TG-SWNIR-CCD
High sensitivity
500 to 1100
TG-SWNIR-MOS
Wide dynamic range
TG-NIR
Back-thinned type
5
(
λ=
550
to
900 nm)
CCD image sensor
5
(
λ=
550
to
1100 nm)
7
900 to 1700
NMOS linear
image sensor
Non-cooled type
TG-cooled NIR-I
Low noise (cooled type)
TG-cooled NIR-II
7
1100 to 2200
InGaAs
linear
image sensor
Low noise (cooled type)
8
9
CMOS linear
image sensor
RC
series
C9407MA
* Typ.
RC-VIS-MOS
Spectrometer module
340 to 780
OEM model
Type No.
Type
Spectral response range (nm)
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
Spectral resolution
Max.
(nm)
Image sensor
CMOS linear
image sensor
RC
series
C9409MA
RC-VIS-MOS
Spectrometer head
340 to 780
9
1