欢迎访问ic37.com |
会员登录 免费注册
发布采购

GMAC97A6 参数 Datasheet PDF下载

GMAC97A6图片预览
型号: GMAC97A6
PDF下载: 下载PDF文件 查看货源
内容描述: 敏感门双向可控硅硅双向晶闸管0.8A , 400V [SENSITIVE GATE TRIACS SILICON BIDIRECTIONAL THYRISTORS 0.8A ,400V]
分类和应用: 可控硅三端双向交流开关
文件页数/大小: 4 页 / 283 K
品牌: GTM [ GTM CORPORATION ]
 浏览型号GMAC97A6的Datasheet PDF文件第1页浏览型号GMAC97A6的Datasheet PDF文件第3页浏览型号GMAC97A6的Datasheet PDF文件第4页  
ISSUED DATE :2005/09/28
REVISED DATE :
Electrical Characteristics
(T
C
= 25 : unless otherwise noted; Electricals apply in both directions)
Characteristic
Off Characteristics
Peak Repetitive Blocking Current (Note2)
(
V
DRM
=400V and V
RRM
=400V; Gate Open)
Symbol
Min
Typ
Max
Unit
T
J
=25 :
T
J
=110 :
I
DRM,
I
RRM
-
-
10
100
1.9
A
On Characteristics
Peak On-State Voltage 2.0 s)
(I
TM
=±0.85A Peak; Pulse Width 2.0ms, Duty Cycle
Gate Trigger Current (Continuous dc)
(V
D
=12.0 Vdc, R
L
=100 )
MT2(+), G(+)
MT2(+), G( - )
MT2( - ), G( - )
MT2( - ), G(+)
Gate Trigger Voltage (Continuous dc)
(V
D
=12.0 Vdc, R
L
=100 )
MT2(+), G(+) All Types
MT2(+), G( - ) All Types
MT2( - ), G( - ) All Types
MT2( - ), G(+) All Types
2.0%)
V
TM
-
-
V
I
GT
-
-
-
-
-
-
-
-
0.1
-
-
-
-
-
-
0.66
0.77
0.84
0.88
-
1.5
2.0
5.0
5.0
5.0
7.0
2.0
2.0
2.0
2.5
-
10
-
mA
V
GT
V
Gate Non-Trigger Voltage
(V
D
=12.0 V, R
L
=100 T
J
=110 : ) All Four Quadrants
Holding Current
(V
D
=12.0 Vdc, Initiating Current=200mA, Gate Open)
Turn-On Time
(V
D
= V
DRM
=400V, I
TM
=1.0A pk, I
G
=25mA)
Dynamic Characteristics
Critical Rate of Rise of Commutation Voltage
(V
D
=V
DRM
=400V, I
TM
=0.84A, Commutation di/dt=0.3A/ms,
Gate Unenergized, T
C
=50 : )
Critical Rate of Rise of Off-State Voltage
(V
D
=V
DRM
=400V, T
C
=110 : , Gate Open, Exponential Waveform)
V
GD
I
H
tgt
V
mA
s
dV/dt (c)
dv/dt
-
-
5.0
25
-
-
V/ s
V/ s
Voltage Current Characteristic of Triacs
(Bidirectional Device)
Symbol
V
DRM
I
DRM
V
RRM
I
RRM
V
TM
I
H
Parameter
Peak Repetitive Forward Off State Voltage
Peak Forward Blocking Current
Peak Repetitive Reverse Off State Voltage
Peak Reverse Blocking Current
Maximum On State Voltage
Holding Current
Quadrant Definitions for a Triac
All polarities are referenced to MT1.
With in-phase signals (using standard AC lines) quadrants
are used
and
GMAC97A6
Page: 2/4