ISSUED DATE :2005/11/09
REVISED DATE :
Function List
Series
CE
High
Low
High
Low
Voltage Output
ON
OFF
ON
OFF
G5M62GR
G5M62GP
Absolute Maximum Ratings
Ta=25 :
Parameter
Input Voltage
Output Current
Output Voltage
CE Input Voltage
Operating Ambient Temperature
Storage Temperature
Continuous Total Power Dissipation
Note: I
OUT
must be less than Pd/(V
IN
-V
OUT
)
Symbol
V
IN
I
OUT
V
OUT
V
CE
Topr
Tstg
PD
Ratings
12
500
V
SS
-0.3 ~V
IN
+0.3
V
SS
-0.3 ~V
IN
+0.3
-30 ~ +80
-40 ~ +125
500
Unit
V
mA
V
V
:
:
mW
Electrical Characteristics
Ta=25 :
G5M62GR-50 V
OUT
(T) =5.0V
(Note1)
Parameter
Symbol
V
OUT
(E)
Output Voltage
(Note2)
Condition
V
IN
=6.0V, I
OUT
=40mA
V
IN
=6V, V
OUT
(E) 4.5V
V
IN
=6V, I
OUT
=1mA to 100mA
I
OUT
=100mA
I
OUT
=200mA
V
IN
=V
CE
=6V
V
IN
=6V, V
CE
=V
SS
I
OUT
=40mA
V
IN
=6V to 10V
Min
180
-
-
-
-
-
-
-
TYP
-
40
165
330
13
-
0.2
-
±100
-
-
-
-0.05
Max
-
80
330
660
21
0.1
0.3
10
-
-
0.25
5.0
0
Unit
V
mA
mV
mV
A
A
%/V
V
ppm/ :
V
V
A
A
Circuit
4.900 5.000 5.100
1
1
1
1
1
2
2
1
-
Max. Output Current
Load Stability
Input-Output
Voltage Differential
Supply Current1
Supply Current2
Input Stability
Input Voltage
Output Voltage
Temperature
Characteristics
CE Input Voltage “High”
CE Input Voltage “Low”
CE Input Current “High”
CE Input Current “Low”
(Note3)
I
OUT max
V
OUT
V
dif1
V
dif2
I
SS
1
I
SS
2
V
OUT
V
IN*
V
OUT
V
IN
V
OUT
Topr
*
V
OUT
V
CEH
V
CEL
I
CEH
I
CEL
I
OUT
=40mA
-30 : Topr 85 :
-
1.5
-
1
1
2
2
V
CE
=V
IN
V
CE
=V
SS
-
-0.2
Note 1: V
OUT
(T) =Specified Output Voltage.
2: V
OUT
(E) =Effective Output Voltage (i.e. the output voltage when “V
OUT
(T) +1.0V” is provided at the V
IN
pin while maintaining a
certain I
OUT
value).
(Note5)
(Note4)
-V
OUT
1
}
3: Vdif={V
IN
1
4: V
OUT
1=A voltage equal to 98% of the Output Voltage whenever an amply stabilized I
OUT {
V
OUT
(T)+1.0V} is input.
5: V
IN
1=The input voltage when V
OUT
1appears as input voltage is gradually decreased.
G5M62GR
Page: 2/8