GS71116ATP/U
AC Test Conditions
Output Load 1
Parameter
Input high level
Input low level
Conditions
VIH = 2.4 V
VI L= 0.4 V
tr = 1V/ns
tf = 1 V/ns
1.4 V
DQ
1
30pF
50
Input rise time
VT = 1.4 V
Input fall time
Input reference level
Output reference level
Output load
Output Load 2
1.4 V
3.3 V
Fig. 1& 2
589
434
DQ
Notes:
1
1. Include scope and jig capacitance.
5pF
2. Test conditions as specified with output loading as shown in Fig. 1
unless otherwise noted.
3. Output load 2 for tLZ, tHZ, tOLZ and tOHZ
Rev: 1.10 3/2009
5/14
© 2001, GSI Technology