GS71024T/U
AC Characteristics
Read Cycle
Parameter
Read cycle time
Address access time
Chip enable access time (CE1, CE2)
MUX control to output valid (V/S)
Output enable to output valid (OE)
Output hold from address change
Output hold from MUX controls change
Chip enable to output in low Z (CE1, CE2)
Output enable to output in low Z (OE)
Chip disable to output in High Z (CE1, CE2)
Output disable to output in High Z (OE)
Symbol
t
RC
t
AA
t
AC
t
AV
t
OE
t
OH
t
OH1
t
LZ*
t
OLZ*
t
HZ*
t
OHZ*
-8
Min
8
—
—
—
—
3
3
3
0
—
—
Max
—
8
8
8
4
—
—
—
—
4
4
Min
9
—
—
—
—
3
3
3
0
—
—
-9
Max
—
9
9
9
4.5
—
—
—
—
4.5
4.5
Min
10
—
—
—
—
3
3
3
0
—
—
-10
Max
—
10
10
10
5
—
—
—
—
5
5
Min
12
—
—
—
—
3
3
3
0
—
—
-12
Max
—
12
12
12
6
—
—
—
—
6
6
Min
15
—
—
—
—
3
3
3
0
—
—
-15
Max
—
15
15
15
7
—
—
—
—
7
7
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
* These parameters are sampled and are not 100% tested
Read Cycle 1: CE = OE = V
IL
, WE = V
IH
t
RC
Address
t
AA
V/S
t
OH
Data Out
Previous Data
t
OH1
t
AV
Data valid
Rev: 1.05 11/2004
6/13
© 1999, GSI Technology
Specifications cited are subject to change without notice. For latest documentation see http://www.gsitechnology.com.