GS70328SJ/TS
Power Supply Currents
0 to 70°C
-40 to 85°C
Parameter Symbol Test Conditions
7 ns 8 ns 10 ns 12 ns 15 ns 7 ns 8 ns 10 ns 12 ns 15 ns
CE ≤ VIL
Operating
Supply
Current
All other inputs
≥ VIH or ≤ VIL
Min. cycle time
IOUT = 0 mA
75 mA 65 mA 50 mA 50 mA 50 mA 80 mA 70 mA 55 mA 55 mA 55 mA
IDD
CE ≥ VIH
Standby
Current
All other inputs
≥ VIH or ≤VIL
Min. cycle time
35 mA 30 mA 25 mA 25 mA 25 mA 40 mA 35 mA 30 mA 30 mA 30 mA
ISB1
ISB2
CE ≥ V – 0.2 V
DD
Standby
Current
All other inputs
1 mA
2 mA
≥ V – 0.2 V or
DD
≤ 0.2 V
AC Test Conditions
Parameter
Output Load 1
Conditions
VIH = 2.4 V
VIL = 0.4 V
tr = 1 V/ns
tf = 1 V/ns
1.4 V
DQ
Input high level
Input low level
1
30pF
50Ω
Input rise time
VT = 1.4 V
Input fall time
Input reference level
Output reference level
Output load
Output Load 2
1.4 V
3.3 V
Fig. 1& 2
589Ω
434Ω
DQ
Notes:
1. Include scope and jig capacitance
1
5pF
2. Test conditions as specified with output loading as shown in Fig. 1
unless otherwise noted
3. Output load 2 for tLZ, tHZ, tOLZ and tOHZ
Rev: 1.11 11/2004
4/11
© 1999, GSI Technology