GS4576S09/18L
Power–Up Initialization Sequence
V
EXT
V
DD
V
DDQ
V
REF
V
TT
200us Min
tCK
tCKH
CK
CK
tDK
tDKL
tDKH
DK
DK
Command
ADDR
BA
DM
D
NOP
NOP
MRS
CODE(1,2)
tCKL
Mode Initialization
tMRSC
Refresh
All Banks(5)
1024 Cycles NOP Cycles Min
MRS
CODE(1,2)
MRS
CODE(2)
NOP
AREF
AREF
NOP
AC
ADDR
Bank 0
Bank 7
Valid
Notes:
1.
2.
3.
4.
5.
Recommend all address pins held Low during dummy MRS commands.
A10–A17 must be Low.
DLL must be reset if tCK or V
DD
are changed.
CK and CK must be separated at all times to prevent bogus commands from being issued.
The sequence of the eight AUTO REFRESH commands (with respect to the 1024 NOP commands) does not matter. As is required for any operation,
tRC must be met between an AUTO REFRESH command and a subsequent VALID command to the same bank.
Rev: 1.03 11/2013
7/63
© 2011, GSI Technology