Table 2-3: AC Electrical Characteristics (Continued)
Parameter
Symbol
Conditions
Min
Typ
Max
Units
Notes
Test
Levels
7
1
1
7
1
Overshoot
–
–
–
SD/HD=0
SD/HD=1
GS9068A
–
Single
Ended
into 75Ω
external load
R
SET
= 750Ω
–
–
–
15
750
–
–
–
–
800
10
8
8
–
850
%
%
%
dB
mV
p-p
2
2
–
–
–
Output Return Loss
Output Voltage
Swing
ORL
V
OUT
Input Voltage
Swing
TEST LEVELS
V
SDI
Differential
300
–
NOTES:
2000
mV
p-p
–
7
1. Production test at room temperature and nominal supply voltage with
guard bands for supply and temperature ranges.
2. Production test at room temperature and nominal supply voltage with
guard bands for supply and temperature ranges using correlated test.
3. Production test at room temperature and nominal supply voltage.
4. QA sample test.
5. Calculated result based on Level 1, 2, or 3.
6. Not tested. Guaranteed by design simulations.
7. Not tested. Based on characterization of nominal parts.
8. Not tested. Based on existing design/characterization data of similar
product.
9. Indirect test.
1. The input coupling capacitor must be set accordingly for
lower data rates.
2. This parameter applies only to the GS1528A.
3. Rise/Fall time measured between 20% and 80%.
GS1528A/GS9068A HD-LINX® II Multi-Rate Dual
Slew-Rate Cable Driver
Data Sheet
30953 - 6
August 2010
7 of 18
Proprietary & Confidential