3.6 UES Error Flag Updating  
CLR1  
CLR0  
MODE OF OPERATION  
Normal  
In receive mode, a UES flag is set HIGH in the outgoing  
EDH packet if the corresponding UES flag was HIGH in the  
incoming packet or if the corresponding V bit was LOW.  
(For example, if the incoming Active Picture V bit is LOW,  
the outgoing Active Picture UES bit will be HIGH). If there is  
no EDH packet in the incoming data, all three UES flags  
(ANC, AP, FF) are set HIGH.  
0
0
1
1
0
1
0
1
Reset Counter to Zero  
Auto Reset  
Hold Counter at Zero  
3.7 No EDH  
reset to zero and begins counting again. The mode of  
operation will immediately return to 00 (normal mode) once  
the counter resets. In "Auto Reset" mode, the counter  
behaves in the normal fashion, except that it resets to zero  
every time a HOSTIF read of the lowest 8 bits of the error  
counter (address 17) is performed. This functionality allows  
the chip to count the number of errors since the last read.  
The “Hold Counter at Zero” mode instantly freezes the  
counter at zero until it is moved into one of the other modes.  
PIN  
LOGIC OPR  
HOST BIT  
NO_EDH  
Some input data streams may lack the EDH packet. In such  
cases, the NO_EDH bit in the HOSTIF read table is  
asserted HIGH. If only a few fields lack the EDH packet, the  
NO_EDH bit will be asserted only for those fields.  
3.9 Flag Port  
In determining if the input data stream contains an EDH  
packet, the GS9021 looks for two things. First, the presence  
of an ANC packet with the header 000 3FF 3FF 1F4 and  
second, that the ANC header is in the right spot for the  
video standard detected. The NO_EDH signal is a logical  
NAND of these two cases. If either one is false, the  
NO_EDH flag is set.  
PIN  
LOGIC OPR  
HOST BIT  
F_R/W  
S[1:0]  
FL[4:0]  
>
OVERWRITE VALUES  
3.8 Errored Field Counter  
In addition to the HOSTIF tables, the EDH error flags can  
also be read and written via the synchronous flag port. The  
five flag port pins, FL[4:0], allow access to all 15 error flags.  
The select pins S[1:0] control which flags are read/written  
as outlined below. If the flag port is not going to be used, it  
is best to set F_R/W HIGH, leave FL[4:0] unconnected and  
set S[1:0] to any value desired but not floating.  
PIN  
LOGIC OPR  
HOST BIT  
ERRORED FIELD COUNTER  
CLR[1:0]  
ERROR SENSITIVITY BITS  
3.9.1 Write Mode  
When the F_R/W pin is LOW, the flag port is in write mode  
and the FL[4:0] pins are configured as inputs. After writing  
to the flag port, the GS9021 inserts the written flags into the  
next outgoing EDH packet. Note that external flag  
overwriting via the flag port takes precedence over HOSTIF  
overwriting but the flag port write only affects the next  
outgoing EDH packet. Following this, if the flag port is not  
written to again, flag operation is returned to normal EDH  
functionality (unless it is being overwritten through the  
HOSTIF).  
The device has a 24 bit ERRORED FIELD COUNTER. The  
counter increments by one on the occurrence of one or  
more error flags in an OUTGOING EDH packet. The error  
flags that can increment the counter are user-selectable  
through the 16 ERROR SENSITIVITY bits in the HOSTIF  
write table.  
The error flag SENSITIVITY bits are active LOW, so that If a  
particular sensitivity bit is set LOW, the counter is sensitive  
to errors of that type in the OUTGOING EDH packet. The  
EDH_CHKSM SENSITIVITY bit is active HIGH.  
The data present on the FL[4:0] output pins, as controlled  
by the S[1:0] pins, is summarized below.  
There are four methods of counter operation. The mode is  
set through 2 bits in the HOSTIF write table, denoted CLR1  
and CLR0.  
In addition to overwriting the 15 error flags, the outgoing  
validity bits for the active picture (APV) and full field (FFV)  
can be overwritten via the flag port.  
In "Normal" mode the counter operates as previously  
discussed, such that the counter increments on detection of  
any error for which the sensitivity flags are set HIGH. If  
“Reset Counter to Zero” mode is selected, the counter is  
11  
521 - 65 - 05