AC ELECTRICAL CHARACTERISTICS
VCC = 5.0V, VEE = 0V, TA = 25°C unless otherwise stated, RLF = 1.8k, CLF1 = 15nF, CLF2 = 3.3pF
TEST
LEVEL
1
PARAMETER
CONDITIONS
MIN
MAX
UNITS
NOTES
TYPICAL
Carrier Detect Response Time
Carrier Applied,
-
3
-
µs
7
6
CL<50pF, RL=open cct.
Carrier Removed,
-
30
-
CL<50pF, RL=open cct.
NOTES
1. TYPICAL - measured on characterization board.
2. Characterized 6 sigma rms.
3. IJT measured with sinusoidal modulation beyond Loop Bandwidth (at 6.5MHz).
4. Synchronous switching refers to switching the input data from one source to another source which is at the same data rate (ie. line 10 switching
for component NTSC).
5. Carrier Loss Time refers to the response of the SDO output from valid re-clocked input data to mute mode when the input signal is removed.
6. Using the DDI input, A/D=0.
7. Using the SDI input, A/D=1.
TEST LEVELS
1. Production test at room temperature and nominal supply voltage with guardbands for supply and temperature ranges.
2. Production test at room temperature and nominal supply voltage with guardbands for supply and temperature ranges using correlated test.
3. Production test at room temperature and nominal supply voltage.
4. QA sample test.
5. Calculated result based on Level 1,2, or 3.
6. Not tested. Guaranteed by design simulations.
7. Not tested. Based on characterization of nominal parts.
8. Not tested. Based on existing design/characterization data of similar product.
BELDEN 8281
CABLE
DATA
DATA
GS9028
CABLE
DRIVER
CHARACTERIZATION
BOARD
TEKTRONIX
GigaBERT
1400
TEKTRONIX
GigaBERT
1400
ANALYZER
TRANSMITTER
CLOCK
TRIGGER
Fig. 1 Test Setup for Figures 5 and 6
4
GENNUM CORPORATION
522 - 80 - 00