This formula is not valid for long, unterminated, or improperly terminated cables.  
This formula should be considered as a starting point, and actual swing values may vary  
based on layout. Also, for large output swings (>1040mV), smaller Rset values may be  
required in order to achieve the desired output swing level at HD and 3G data rates.  
Table 4-5: Typical RSET Values  
Output Swing (mV)  
RSET (Ω)  
1800*  
800  
332  
750  
500  
1210  
*NOTE: In order to generate output swings greater than 1040mV, VCC_TERM must be  
connected to a 5V supply.  
4.7 Output Return Loss Measurement  
The GS2988 has a feature which allows users to measure ORL reliably while the device  
is still powered. The device can be put into a BALANCE mode which prevents the  
outputs from toggling while the device is powered on, allowing the ORL to be measured  
while the device is still powered.  
When EQ_EN is LOW while SD/HD is HIGH, the device goes into BALANCE mode. This  
mode is used during ORL measurement, disabling the AC signal path of the device  
without powering it down. When in BALANCE mode, the device produces equal  
pull-down currents in both differential shoulders of the serial data differential output,  
effectively stopping the output at the output common mode voltage level. Gennum  
recommends using BALANCE mode when measuring ORL with 2.5V termination  
voltage.  