VC-80 Series
■ REFLOW MOUNTING CONDITIONS (RECOMMENDED)
• Perform mounting using the temperature profile shown below. To prevent thermal stress to the VCO, ensure
gentle temperature gradients and use preheating whenever possible. (Recommended preheating: 140 °C to
160 °C for 60 s ± 20 s)
• Always consult FUJITSU MEDIA DEVICE beforehand if mounting more than once.
• Never remove a VCO that has already been mounted and attempt to reuse.
• For mounting, use a general-purpose flux suitable for mounting electronic components.
7 s Max.
250
230 ± 10
2
200
1
20 s 30 s
160
150
140
60 s ± 20 s
100
50
Cooling
Heating
Warm-up
Pre-heating
Time (s)
0
1 : 10 °C/s or less
2 : 8 °C/s or less
■ WASHING CONDITIONS
• Washing solution: Use isopropyl alcohol.
• Washing procedure: Immersion or steam cleaning is recommended.
• Washing time: For immersion: Less than 5 minutes at 40 °C or less.
For steam: Less than 2 minutes at 90 °C or less is recommended.
12