 浏览型号MBM29LV160TE-70的Datasheet PDF文件第4页浏览型号MBM29LV160TE-70的Datasheet PDF文件第5页浏览型号MBM29LV160TE-70的Datasheet PDF文件第6页浏览型号MBM29LV160TE-70的Datasheet PDF文件第7页浏览型号MBM29LV160TE-70的Datasheet PDF文件第9页浏览型号MBM29LV160TE-70的Datasheet PDF文件第10页浏览型号MBM29LV160TE-70的Datasheet PDF文件第11页浏览型号MBM29LV160TE-70的Datasheet PDF文件第12页  
MBM29LV160TE/BE-70/90/12  
DEVICE BUS OPERATIONS  
Table 2 MBM29LV160TE/BE User Bus Operation (BYTE = VIH)  
DQ0 to DQ15  
Operation  
CE  
OE  
WE  
A0  
A1  
A6  
A9  
RESET  
Auto-Select Manufacture Code (1)  
Auto-Select Device Code (1)  
Read (3)  
L
L
L
H
L
L
L
L
X
X
L
L
H
H
H
X
H
L
L
H
A0  
X
X
A0  
L
L
L
L
L
VID  
VID  
A9  
X
Code  
Code  
DOUT  
H
H
H
H
H
H
H
H
VID  
L
L
A1  
X
A6  
X
X
A6  
L
Standby  
X
H
H
VID  
L
HIGH-Z  
HIGH-Z  
DIN  
Output Disable  
X
X
Write (Program/Erase)  
Enable Sector Protection (2), (4)  
Verify Sector Protection (2), (4)  
Temporary Sector Unprotection (5)  
Reset (Hardware)/Standby  
A1  
H
H
X
A9  
VID  
VID  
X
X
H
X
X
L
L
Code  
X
X
X
X
X
X
X
X
X
HIGH-Z  
Table 3 MBM29LV160TE/BE User Bus Operation (BYTE = VIL)  
DQ15 /  
Operation  
CE OE WE  
A0  
A1  
A6  
A9  
DQ0 to DQ7  
RESET  
A-1  
Auto-Select Manufacture Code (1)  
Auto-Select Device Code (1)  
Read (3)  
L
L
L
H
L
L
L
L
X
X
L
L
H
H
H
X
H
L
L
L
H
A0  
X
X
A0  
L
L
L
L
L
VID  
VID  
A9  
X
Code  
Code  
DOUT  
H
H
H
H
H
H
H
H
VID  
L
L
L
A-1  
X
A1  
X
A6  
X
X
A6  
L
Standby  
X
H
H
VID  
L
HIGH-Z  
HIGH-Z  
DIN  
Output Disable  
X
X
X
Write (Program/Erase)  
Enable Sector Protection (2), (4)  
Verify Sector Protection (2), (4)  
Temporary Sector Unprotection (5)  
Reset (Hardware)/Standby  
A-1  
L
A1  
H
H
X
A9  
VID  
VID  
X
X
H
X
X
L
L
L
Code  
X
X
X
X
X
X
X
X
X
X
X
HIGH-Z  
L = VIL, H = VIH, X = VIL or VIH.  
= Pulse input. See DC Characteristics for voltage levels.  
Legend:  
Notes: 1. Manufacturer and device codes may also be accessed via a command register write sequence. See  
Table 7.  
2. Refer to the section on Sector Protection.  
3. WE can be VIL if OE is VIL, OE at VIH initiates the write operations.  
4. VCC = 3.3 V ±10%  
5. It is also used for the extended sector protection.  