MB89160/160A Series
6
5
4
3
2
1
Analog accurancy
assured in the
AVCC = VCC = 3.5 V
to 6.0 V range
Operation assurance range
(MHz)
1
2
3
4
Main clock operating frequency
(µs)
4.0
2.0
1.0
Minimum execution time (instruction cycle)
Figure 2 Operating Voltage vs. Main Clock Operating Frequency (Dual-clock MB8916X/A)
Figures 1 and 2 indicate the operating frequency of the external oscillator at an instruction cycle of 4/FCH.
Since the operating voltage range is dependent on the instruction cycle, see minimum execution time if the
operating speed is switched using a gear.