MB95120MB Series
2. Recommended Operating Conditions
Condi-
(AVSS = VSS = 0.0 V)
Value
Parameter
Symbol
Unit
Remarks
tion
Min
Max
2.42*1,*2
5.5*1
In normal operating
Other than
MB95FV100D-103
Hold condition in
STOP mode
2.3
5.5
5.5
5.5
Power supply
voltage
VCC,
AVCC
V
2.7
In normal operating
MB95FV100D-103
Hold condition in
STOP mode
2.3
The range of liquid crystal power supply
(The optimal value depends on liquid
crystal display elements used.)
Power supply
voltage for LCD
V0 to V3
AVR
VSS
VCC
V
V
⎯
A/D converter
reference
input voltage
4.0
0.1
AVCC
1.0
Smoothing
capacitor
CS
TA
μF *3
− 40
+ 5
+ 105
+ 35
°C Other than MB95FV100D-103
°C MB95FV100D-103
Operating
temperature
*1 : The values vary with the operating frequency, machine clock or analog guarantee range.
*2 : The value is 2.88 V when the low voltage detection reset is used.
*3 : Use a ceramic capacitor or a capacitor with equivalent frequency characteristics. A bypass capacitor of VCC
pin must have a capacitor value higher than CS. For connection of smoothing capacitor CS, refer to the diagram
below.
• C pin connection diagram
C
C
S
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
representatives beforehand.
36