MB95120MB Series
■ MASK OPTION
MB95F124MB/F124NB/F124JB
MB95F126MB/126NB/F126JB
MB95F128MB/F128NB/F128JB
Part number
MB95128MB
MB95FV100D-103
Setting disabled
No.
Specify when
ordering MASK
Specifying procedure
Setting disabled
Clock mode select
• Single-system clock mode
• Dual-system clock mode
Changing by the
switch on
Dual-system clock
mode
1
Dual-system clock mode
MCU board
Low voltage detection reset*
• With low voltage detection
reset
• Without low voltage detection
reset
Changing by the
switch on
Specify when
ordering MASK
Specified by part
number
2
3
MCU board
Clock supervisor*
• With clock supervisor
• Without clock supervisor
Changing by the
switch on
Specify when
ordering MASK
Specified by part
number
MCU board
MCU board switch set
as following ;
Reset output*
• With reset output
• Without reset output
• With supervisor :
Specify when
ordering MASK
Specified by part
number
4
Without reset
output
• Without supervisor :
With reset output
Fixed to oscillation Fixed to oscillation
stabilization wait stabilization wait time of
time of (214−2) /FCH (214−2) /FCH
Fixed to oscillation
stabilization wait time
of (214−2) /FCH
Oscillation stabilization
wait time
5
* : Refer to table below about clock mode select, low voltage detection reset, clock supervisor select and reset output.
74