MB39A104
Example:
CH1
2 (VIN − VO)
L
≥
ton
IO
2 × (19 − 5)
1
≥
×
× 0.263
IO
500 × 103
≥ 4.91 µH
CH2
2 (VIN − VO)
L
≥
ton
IO
2 × (19 − 3.3)
1
≥
×
× 0.174
IO
500 × 103
≥ 3.64 µH
Inductance values derived from the above formulas are values that provide sufficient margin for continuous
operation at maximum load current, but at which continuous operation is not possible at light loads. It is therefore
necessary to determine the load level at which continuous operation becomes possible. In this application, the
Sumida CDRH104R-150 is used. At 15 µH, the load current value under continuous operating conditions is
determined by the following formula.
Load current value under continuous operating conditions : IO
VO
2L
IO
≥
toff
Example: Using the CDRH104R-150
15 µH (allowable tolerance ±30%) , rated current = 3.6 A
CH1
VO
2L
IO ≥
toff
5
1
≥
×
× (1 − 0.263)
2 × 15 × 10−6
500 × 103
≥ 245.7 mA
CH2
VO
toff
2L
IO
≥
3.3
1
≥
× (1 − 0.174)
2 × 15 × 10−6 × 500 × 103
≥ 181.7 mA
27