MB39A104  
ABOUT TIMER-LATCH PROTECTION CIRCUIT  
1. Setting Timer-Latch Overcurrent Protection Detection Current  
The overcurrent protection circuit is actuated upon completion of the soft-start period. When an overcurrent  
flows, the circuit detects the increase in the voltage between the FET’s drain and source using the external FET  
ON resistor (RON), actuates the timer circuit, and starts charging the capacitor CSCP connected to the CSCP  
terminal (pin 8). If the overcurrent remains flowing beyond the predetermined period of time, the circuit sets the  
latch to fix OUT terminals (pin 3, 22) at “H” level and turn off the external FET. The detection current value can  
be set by the resistors (RLIM1 and RLIM2) connected between the FET’s drain and the ILIM1 terminal (pin 5) and  
between the drain and the ILIM2 terminal (pin 20), respectively.  
The internal current (ILIM) can be set by the timing resistor (RT) connected to the RT terminal (pin 12).  
Time until activating timer circuit and setting latch is equal to short-circuit detection time in "2. Setting Time  
Constant for Timer-Latch Short-Circuit Protection Circuit".  
Internal current value: ILIM  
2700  
ILIM (µA) =:  
RT (k)  
Detection current value: IOCP  
ILIM(A) × RLIM()  
RON ()  
(VIN(V) VO(V)) × VO(V)  
2 × VIN(V) × fOSC(Hz) × L(H)  
IOCP (A) =:  
RLIM : Overcurrent detection resistor  
RON : External FET ON resistor  
VIN : Input voltage  
VO : DC/DC converter output voltage  
fOSC : Oscillation frequency  
L
: Coil inductance  
To reset the actuated protection circuit, either the power supply turn off and on again or set the CTL terminal  
(pin 24) to the "L" level to lower the VREF terminal (pin 17) voltage to 2.4 V (Min) or less.  
• Overcurrent detection circuit  
VIN  
Q1  
L
(VS2)  
VS1  
21  
4
VO  
(ILIM2)  
+
Current  
Protection  
Logic  
20  
ILIM1  
(RLIM)  
5
(1 µA)  
Each  
Channel  
Drive  
CSCP  
8
VREF  
UVLO  
S
Latch  
R
17  