Pre-amplified/5V Excitation/Gauge
■Connection
diagram■
View from Lavel
XFPN
Data sheet
■Transfer
Function■
Vout = Vs×( P×α+β) ± (Pressure Error×Temperature Error Multiplier×α×Vs)
Vs=Vcc=5.0V
P=Input pressure(kPa)
Model
XFPN-03PGV
XFPN-100KPGV
XFPN-025KPG
XFPN-050KPG
XFPN-100KPG
XFPN-200KPG
XFPN-03PGVR
XFPN-100KPGVR
XFPN-025KPGR
XFPN-050KPGR
XFPN-100KPGR
XFPN-200KPGR
Measurable
pressure
range(kPa)
0 to -24.5
0 to -100
0 to 25
0 to 50
0 to 100
0 to 200
α
-0.03266
-0.008
0.032
0.016
0.008
0.004
β
0.1
0.1
0.1
0.1
0.1
0.1
Pressure Error
(kPa)
0.612
2.5
0.625
1.25
2.5
5
Temperature Error Multiplier
Marking
3