Pre-amplified/5V Excitation/Gauge
XFPM,XFHM Data sheet
Connection diagram
XFPM, XFHM
Vcc(DC5V)
Vcc
Vout
GND
Vout
C2
Remarks :
C1
1) C1 : Connect 680pF capacitor within 2cm distance from
leads.
2) C2 : Connect 0.01 F or more capacitor within 2cm dis-
tance from leads.
GND
3) 4 and 5 pins must be No Connection. Open them as float-
ing ones completely, and do NOT connect to other line or
each other.
Transfer Function
Vout=Vs (P
Vs=5.0volts
+
)
(Pressure Error Temperature Error Multiplier
Vs)
Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage.
P=Input Pressure(kPa)
Model
025KPG(D)
050KPG(D)
100KPG(D)
100KPGV
100KPGW(DW)
200KPG(D)
001MPG(D)
115KPA
pressure range
Pressure Error(kPa)
0
0
25kPa
50kPa
0.036
0.018
0.009
0.009
0.0045
0.0045
0.0009
0.009
0.04
0.04
0.04
0.04
0.49
0.04
0.04
0.095
0.625
1.25
2.5
2.5
5.0
5.0
25
2.5
0
0
100kPa
100kPa
100 +100kPa
0
0
200kPa
1MPa
15 115kPa.abs
Temperature Error Multiplier
3.5
3
2.5
2
1.5
1
0.5
0
85
125
120
-
40
-
20
0
20
40
60
80
100
Temperature
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
4
E-mail : sensor@fujikura.co.jp