Pre-amplified/5V Excitation/Absolute
XFPM,XFAM Data sheet
Connection diagram
XFPM (Absolute pressure)
Vcc(DC5V)
Vcc
Vout
GND
Vout
C2
Remarks :
C1
1) C1 : Connect 680pF capacitor within 2cm distance
from leads.
2) C2 : Connect 0.01 F or more capacitor within 2cm dis-
tance from leads.
3) 2 and 3 pins must be No Connection. Open them as
float-ing ones completely, and do NOT connect to other
GND
line or each other.
XFAM
Vcc(DC5V)
GND
Vout
Vcc
Vout
C2
C1
Remarks :
1) C1 : Connect 680pF capacitor within 2cm distance from
leads.
2) C2 : Connect 0.01 F or more capacitor within 2cm dist-
ance from leads.
3) 4 and 5 pins must be No Connection. Open them as
GND
float-ing ones completely, and do NOT connect to other
line or each other.
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.