Pre-amplified/3V Excitation/Absolute
Connection diagram
X3PM,X3AM Data sheet
X3PM (Absolute pressure)
Vcc(DC3V)
Vcc
Vout
Vout
GND
Remarks :
C2
C1
1) C1 : Connect 680pF capacitor within 2cm distance
from leads.
2) C2 : Connect 0.01 F or more capacitor within 2cm
distance from leads.
3) 2 and 3 pins must be No Connection. Open them as
floating ones completely, and do NOT connect to
other line or each other.
GND
X3AM
Vcc(DC3V)
GND
Vout
Vout
Vcc
C2
Remarks :
1) C1 : Connect 680pF capacitor within 2cm distance from
leads.
2) C2 : Connect 0.01 F or more capacitor within 2cm dis-
tance from leads.
3) 4 and 5 pins must be No Connection. Open them as float-
ing ones completely, and do NOT connect to other line or
each other.
C1
GND
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
4
E-mail : sensor@fujikura.co.jp