Pre-amplified/3V Excitation/Gauge
X3PM,X3HM Data sheet
Connection diagram
X3PM, X3HM
Vcc(DC5V)
Vcc
Vout
GND
Vout
C2
C1
Remarks :
1)C1 : Connect 680pF capacitor within 2cm distance from leads.
2)C2 : Connect 0.01 F or more capacitor within 2cm distance from
GND
leads.
3)4 and 5 pins must be No Connection. Open them as floating ones
completely, and do NOT connect to other line or each other.
Transfer Function
Vout=Vs (P
Vs=3.0volts
+
)
(Pressure Error Temperature Error Multiplier
Vs)
Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage.
P=Input Pressure(kPa)
Model
050KPG(D)
100KPG(D)
100KPGV(DV)
100KPGW(DW)
200KPG(D)
001MPG(D)
115KPA
pressure range
Pressure Error(kPa)
0
0
50kPa
100kPa
100kPa
0.01
0.005
0.005
0.0025
0.0025
0.0005
0.005
0.1667
0.1667
0.1667
0.4167
0.1667
0.1667
0.09167
2.5
5.0
5.0
10.0
10.0
50.0
5.0
0
100 +100kPa
0
0
200kPa
1MPa
15 115kPa.abs
Temperature Error Multiplier=1
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
4
E-mail : sensor@fujikura.co.jp