Pre-amplified/3V Excitation/Differential
X3DM Data sheet
Outline dimensions
Unit : mm
0.15
X3DM
8
3.5
Pressure port 2
6
Labelled faceplate
Projections
4
5
6
5
4
0.5
Pressure port 1
R0.5
0.8
1
2
3
1
3
2
1
1
2.54
2.54
Recommended footprint for PCB
2- 1.2(Holes for projections)
2
Index direction
11
1
Land-pads
16.6
(Unit : mm)
Zooming up the projections
3.4
Index
Connection diagram
X3DM
Vcc(DC3V)
Vcc
Vout
GND
Vout
Remarks :
1) C1 : Connect 680pF capacitor within 2cm distance from
leads.
C2
C1
2) C2 : Connect 0.01 F or more capacitor within 2cm
distance from leads.
3) 4 and 5 pins must be No Connection. Open them as float-
ing ones completely, and do NOT connect to other line or
each other.
GND
Transfer Function
Vout=Vs (P
Vs=3.0volts
+
)
(Pressure Error Temperature Error Multiplier
Vs)
Notes ; The output voltage (Vout) is no perfect ratiometric with the power supply voltage.
P=Input Pressure(kPa)
Model
050KPG(D)
100KPG(D)
100KPGV
100KPGW(DW)
200KPG(D)
001MPGW(D)
115KPA
pressure range
Pressure Error(kPa)
0
0
50kPa
100kPa
100kPa
+100kPa
200kPa
+1MPa
0.01
0.005
0.005
0.0025
0.0025
0.0025
0.005
0.1667
0.1667
0.1667
0.4667
0.1667
0.1667
0.09167
2.5
5.0
5.0
10.0
10.0
50.0
5.0
0
0
0
0
15 115kPa.abs
Temperature Error Multiplier=1
Note ; Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
If you have any questions regarding technical issues or specifications, please contact us.
Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538
2