Freescale Semiconductor, Inc.  
Ana log Sub syste m  
8.7 Volta g e Me a sure m e nt Me thod s  
The methods for obtaining a voltage measurement can use software  
techniques to express these voltages as absolute or ratiometric  
readings.  
In most applications the external capacitor, the clock source, the  
reference voltage and the charging current may vary between devices  
and with changes in supply voltage or ambient temperature. All of these  
variations must be considered when determining the desired resolution  
of the measurement. The maximum and minimum extremes for the full  
scale count will be:  
N
= C  
x V  
x f  
/ (P x I  
)
CHGMAX  
FSMIN  
EXTMIN  
FSMIN  
OSCMIN  
N
= C  
x V  
x f  
/ (P x I  
)
CHGMIN  
FSMAX  
EXTMAX  
FSMAX  
OSCMAX  
The minimum count should be the desired resolution; and the counting  
mechanism must be capable of counting to the maximum. The final  
scaling of the count will be by a math routine which calculates:  
V = V  
x (N - N  
) / (N  
- N  
)
X
REF  
X
OFF  
REF  
OFF  
Where:  
V
V
= Known reference voltage  
= Unknown voltage between V and V  
REF  
X
SS  
REF  
N
N
N
= Conversion count for unknown voltage  
= Conversion count for known reference voltage (V  
= Conversion count for minimum reference voltage (V )  
X
)
REF  
REF  
OFF  
SS  
When V  
is a stable voltage source such as a zener or other reference  
REF  
source, then the unknown voltage will be determined as an absolute  
reading. If V is the supply source to the device (V ), then the  
REF  
DD  
unknown voltage will be determined as a ratio of V , or a ratiometric  
DD  
reading.  
If the unknown voltage applied to the comparator is greater than its  
common-mode range (V –1.5 volts), then the external capacitor will  
DD  
try to charge to the same level. This will cause both comparator inputs  
to be above the common-mode range and the output of the comparator  
will be indeterminate. In this case the comparator output flags may also  
be set even if the actual voltage on the positive input (+) is less than the  
General Release Specification  
MC68HC705JJ7/MC68HC705JP7 Rev. 3.0  
Analog Subsystem  
For More Information On This Product,  
Go to: www.freescale.com