FUNCTIONAL DESCRIPTION  
FUNCTIONAL INTERNAL BLOCK DESCRIPTION  
operation, or shuts down after a failure to regain normal  
operation.  
changed via I2C at any time after power up has successfully  
completed.  
• A hard over-current limit (short-circuit limit) that is higher  
than the cycle by cycle limit at which the device reacts by  
shutting down the output immediately. This is necessary to  
prevent damage in case of a short-circuit. After that, only  
GrpB will attempt a one time retry after a time-out period of  
10 ms and will go through a new soft start cycle  
Phase Control  
REG1 to REG5 use the main Switching frequency FSW1,  
which is configured through the FREQ terminal at power up.  
FSW1 uses 4 different phases of switching (clock is 80  
degrees out of phase) to spread out the current draw by the  
individual converters from the input supply over time to  
reduce the peak input current demand. The remaining  
regulators use FSW2 which can be programmed at any time  
via I2C after a successful power up sequence.  
Output Over-voltage/Under-voltage Monitoring  
In the case of an output over-voltage/under-voltage, the  
user has two options that can be programmed through the  
I2C interface:  
Fault Register  
Response A: The output will switch off automatically and  
the 34704 would alert the processor through I2C that such an  
event happened.  
The 34704 has a dedicate fault register accessible via I2C  
which indicate which regulator is detecting a fault situation. In  
addition to this, each channel has its own fault register which  
indicates the type of fault detected in that regulator.  
Response B: The output will not switch off. Rather the  
34704 communicates to the processor that an over-voltage/  
under-voltage condition has occurred and waits for the  
processor decision to either shutoff or not; in the mean time  
the control loop will try to fix itself.  
I2C communication and Registers  
The 34704 can communicate using a standard I2C,  
communication protocol or an accurate I2C protocol. During  
the first one, the device processes the given command as  
soon as it has received it. During the accurate data  
communication, the device requires that each read/write  
command be sent twice to validate the data. The 34704  
provides a user accessible register map that allows various  
general IC configurations as well as independent control of  
each regulator, including fault flag registers and all  
configurable features for each regulator.  
NOTE: If Response A is set on any of the regulators from  
GrpB, and a OV/UV event occurs in the correspondig  
regulator, the complete device will shutdown and try to restart  
as long as the OV/UV is no longer present. This will also set  
the RST signal low until REG2, 3 and 4 are on regulation.  
LOGIC AND CONTROL  
Startup Sequencing  
At power up, the VG regulator starts ramping up in peak  
detect mode. Meanwhile, VDDI is tracking VG until it reaches  
regulation and releases a POR signal that enables the  
internal circuitry and reads the FREQ and SS configuration to  
ramp up REG2, REG3 and REG4, that serve as the MPU  
main power supplies. Once the MPU is up, I2C  
communication is available to enable or disable GrpA, GrpC,  
GrpD and GrpE. An extra sequence can be configured for  
REG5, REG6 and REG7, changing the order in which they  
ramp up when enabled. See Power-Up Sequence on page  
28.  
OUTPUT GROUPS - REGULATORS  
The 34704 is divided in 5 different groups which are  
arranged as follows:  
• GrpA: Includes REG1(26) (VOUT1)  
• GrpB: Includes REG2, REG3, and REG4  
• GrpC: Includes REG5, REG6(26), and REG7(26)  
• GrpD: Includes REG8  
• GrpE: This is a special group. It includes REG5 when  
GrpC/E power sequencing option#1 is chosen  
Turning on/off each group would cause all contained  
regulators to turn on/off.  
Soft Start Control  
During power up the 34704 reads the SS terminal to  
configure a default soft start timing for all regulators when  
these are enabled. Soft start for REG5 to REG8 can be  
Notes  
26. Only on 34704A  
34704  
Analog Integrated Circuit Device Data  
Freescale Semiconductor  
21  