Output OFF Open Load Fault
Output Voltage Shutdown
An Output OFF Open Load Fault is the detection and
reporting of an open load when the corresponding output is
disabled (input bit programmed to a logic low state). The
Output OFF Open Load Fault is detected by comparing the
drain-to-source voltage of the specific MOSFET output to an
internally generated reference. Each output has one
dedicated comparator for this purpose.
An over voltage condition on VDD (> 7.0) may result in
permanent damage to the 33800. Over-voltage on the VPWR
pin will cause the 33800 to shut down until the voltage returns
to a normal value. Over voltage exceeding the maximum
recommended voltage (45V) may cause permanent damage
to the 33800.
Each output has an internal pull-down current source or
resistor. The pull-down current sources are enabled on
power-up and must be enabled for Open Load Detect to
function. In cases were the Open Load Detect current is
disabled, the status bit will always respond with logic 0. The
device will only shut down the pull-down current in Sleep
Mode or when disabled via the SPI.
Output Voltage Clamp
Each output of the 33800 incorporates an internal voltage
clamp to provide fast turn-OFF and transient protection of
each output. Each clamp independently limits the drain-to-
source voltage to 50V. The total energy clamped (EJ) can be
calculated by multiplying the current area under the current
curve (IA) times the clamp voltage (VCL) (see Figure 10).
During output switching, especially with capacitive loads,
a false Output OFF Open Load Fault may be triggered. To
prevent this false fault from being reported, an internal fault
filter of 100µs to 450µs is incorporated. The duration for
which a false fault may be reported is a function of the load
impedance, RDS(ON), COUT of the MOSFET, as well as the
supply voltage, VPWR. The rising edge of CS triggers the built-
in fault delay timer. The timer must time out before the fault
comparator is enabled to detect a faulted threshold. Once the
condition causing the Open Load Fault is removed, the
device resumes normal operation. The Open Load Fault,
however, will be latched in the output SO Response register
for the MCU to read.
Characterization of the output clamps, using a single pulse
non-repetitive method at 0.3A, indicates the maximum
energy to be 50mJ at 150°C junction temperature per output.
.
Drain-to-SourceClamp
Drain-to-Source Clamp
Voltage (V = 45 V)
50V)
Drain Voltage
Drain Voltage
CL
Voltage (VCL = 50V)
Clamp Energy
Clamp Energy
Drain Current
Drain Current
(I = 0.3 A)
(IDD= 0.3A)
(EJ = IA x V
)
(EJ = IA xCVLCL
)
Drain-to-SourceON
Drain-to-Source ON
Voltage (VDS(O N))
Voltage (VDS(ON)
)
Current
Area (I )
Under-voltage Shutdown
A
Time
Time
GND
GND
An under-voltage condition on VDD results in the global
shutdown of all outputs and reset of all control registers. The
under-voltage threshold is between 0.8 and 2.8V.
Figure 10. Output Voltage Clamping
An under-voltage condition on VPWR also results in the
global shutdown of all outputs and reset of all control
registers. The under-voltage threshold is between 3.0 and
4.4V
Reverse Battery Protection
The 33800 device requires external reverse battery
protection on the VPWR pin.
All outputs consist of a power MOSFET with an integral
substrate diode. During reverse battery condition, current will
flow through the load via the substrate diode. Under this
circumstance relays may energize and lamps will turn on. If
load reverse battery protection is desired, a diode must be
placed in series with the load.
Low-voltage condition (4.4V< VPWR <9.0V) will operate
per the command word, however status reported on SO pin
is not guaranteed and performance may be out of
specification limits.
33800
Analog Integrated Circuit Device Data
Freescale Semiconductor
35