F75386
0.5℃error.
9. Electrical characteristic
9.1 Absolute Maximum Ratings
PARAMETER
RATING
UNIT
V
Power Supply Voltage
Input Voltage
-0.5 to 5.5
-0.5 to VDD+0.5
0 to +140
V
Operating Temperature
Storage Temperature
° C
° C
-55 to 150
Note: Exposure to conditions beyond those listed under Absolute Maximum Ratings may adversely affect the life and reliability of
the device
9.2 DC Characteristics
(TA = 0° C to 70° C, VDD = 3.3V ± 10%, VSS = 0V )
Parameter
Conditions
MIN
TYP
± 1
± 1
± 1
3.3
MAX Unit
Temperature Error, Remote Diode
60 oC < TD < 126 oC, VCC = 3.0V to 3.6V
0 oC <TD < 60 oC; 126 oC <TD < 145 oC;
0 oC < TA < 100 oC, VCC = 3.0V to 3.6V
oC
± 3
Temperature Error, Local Diode
Supply Voltage range
oC
± 3
3.0
3.6
V
Average operating supply current
16 Conversions / Sec Rate
630
430
5
uA
uA
uA
oC
V
0.0625 Conversions / Sec Rate
Standby supply current
Resolution
0.125
2.55
2.2
Under-voltage lockout threshold
Power on reset threshold
Diode source current
VDD input, Disables ADC , Rising Edge
2.4
V
High Level
Low Level
95
uA
uA
10
-19-
F75386
July, 2007
V0.27P