F75386  
7.8 ALERT MASK Register 2Index 17h  
Power on default <7:0> = 00h  
T3 = Pin 3 external temperature sensor (Remote)  
Bit  
Name  
Attribute  
Description  
Set to 1, T3 temperature exceeds its THERM limit will not generate an ALERT.  
Set to 0, T3 temperature exceeds its THERM limit will generate an ALERT.  
These bits are unused and always set to 0  
7
T1_THR_MASK  
Reserved  
RO  
6-5  
4
RO  
Set to 1, T3 temperature exceeds high limit will not generate an ALERT.  
Set to 0, T3 temperature exceeds high limit will generate an ALERT.  
Set to 1, T3 temperature goes below low limit will not generate an ALERT.  
Set to 0, T3 temperature goes below low limit will generate an ALERT.  
This bit is unused and always set to 0  
T3H_MASK  
RO  
3
2
1
0
T3L_MASK  
Reserved  
RO  
RO  
RO  
RO  
Set to 1, T3 temperature exceeds its THERM limit will not generate an ALERT.  
Set to 0, T3 temperature exceeds its THERM limit will generate an ALERT.  
This bit is unused and always set to 0  
T3_THR_MASK  
Reserved  
7.9 PWM Control Register Index 30h  
Power on default <7:0> = 20h  
Bit  
7
Name  
Attribute  
R/W  
Description  
Set method of controlling PWM duty and frequency to FINTEK mode.  
This bit is unused and always set to 0  
FTK_MODE  
Reserved  
6
RO  
When bit7 set to 0, tachometer input filter can be selected here.  
2’b00: Filter time = 177.6us  
2’b01: Filter time = 355.2us  
2’b10: Filter time = 888us  
5-4  
FLT_SEL  
R/W  
2’b11: Filter time = 1.776ms  
3
2
Reserved  
RO  
This bit is unused and always set to 0  
Set to 1, disable the clock adjustment for different operating temperature.  
Set to 0, enable the clock adjustment for different operating temperature.  
Set to 1, select PWMOUT output.  
DIS_CLKCTRL  
R/W  
1
0
PT_SEL  
ONE_T  
R/W  
R/W  
Set to 0, select THERM# output.  
Set to 1, select only one external thermal diode. At this mode, T3(2nd external) ‘s reading  
and status will be set to FFh and 00h.  
Set to 0, select two external thermal diodes.  
-13-  
F75386  
July, 2007  
V0.27P  