F75383/F75384
around 6 to 12 feet.
7. Because the measurement technique uses switched current sources, excessive cable and/or filter capacitance will affect the
measurement accuracy. When using long cables, the filter capacitor may be reduced or removed. Cable resistance can also
induce errors. 1 Ω series resistance introduces about 0.5℃error.
7. Registers Description
7.1 Configuration Register Index 03h(Read), 09h(Write)
Power on default <7:0> = 00h
Bit
7
Name
Attribute
R/W
Description
ALERT_MASK
RUN_STOP
Reserved
Set to 1, mask ALERT# signal output.
Set to 0, monitor. Set to 1, stop to monitor(software power down).
6
R/W
5-0
7.2 Status Register Index 02h
Power on default <7:0> = 00h
Bit
Name
Attribute
RO
Description
7
ADC_BUSY
VT1HIGH
Set to 1, ADC is converting.
6
5
4
3
RO
Set to 1, VT1 temperature exceeds high limit.
Set to 0, VT1 temperature does not exceed high limit.
Set to 1, VT1 temperature goes below low limit.
Set to 0, VT1 temperature does not goes below low limit.
Set to 1, VT2 temperature exceeds high limit.
Set to 0, VT2 temperature does not exceed high limit.
Set to 1, VT2 temperature goes below low limit.
Set to 0, VT2 temperature does not goes below low limit.
Set to 1, VT2 is open-circuit.
VT1LOW
VT2HIGH
VT2LOW
RO
RO
RO
2
1
0
OPEN
RO
RO
RO
VT2THERM
VT1THERM
Set to 1, VT2 temperature exceeds its THERM limit.
Set to 1, VT1 temperature exceeds its THERM limit.
VT1(Local) ; VT2(Remote)
F75383/F75384
-9-
July, 2007