Feature Integration Technology Inc.
Fintek
F75373
7-0 BOUND1TMP
R/W
The 1st BOUNDARY temperature for VT2 in temperature mode.
When VT2 temperature is exceed this boundary, FAN2 segment 1
speed count registers(INDEX B4h, B5h) will be loaded into FAN1
expect count registers(INDEX 84h,85h).
When VT2 temperature is below this boundary, FAN2 segment 2
speed count registers(INDEX B6h, B7h) will be loaded into FAN2
expect count registers(INDEX 84h,85h).
6.62
VT2 BOUNDARY 2 TEMPERATURE – Index B1h
Power-on default [7:0] =0000_0000b
Bit
Name
Attribute
Description
7-0
BOUND2TMP
R/W
The 2nd BOUNDARY temperature for VT2 in temperature mode.
When VT2 temperature is exceed this boundary, FAN2 segment 2
speed count registers(INDEX B6h, B7h) will be loaded into FAN2
expect count registers(INDEX 84h,85h).
When VT2 temperature is below this boundary, FAN2 segment 3
speed count registers(INDEX B8h, B9h) will be loaded into FAN2
expect count registers(INDEX 84h,85h).
6.63
VT2 BOUNDARY 3 TEMPERATURE – Index B2h
Power-on default [7:0] =0000_0000b
Bit
Name
Attribute
Description
7-0
BOUND3TMP
R/W
The 3rd BOUNDARY temperature for VT2 in temperature mode.
When VT2 temperature is exceed this boundary, FAN2 segment 3
speed count registers(INDEX B8h, B9h) will be loaded into FAN2
expect count registers(INDEX 84h,85h).
When VT2 temperature is below this boundary, FAN2 segment 4
speed count registers(INDEX BAh, BBh) will be loaded into FAN2
expect count registers(INDEX 84h,85h).
35
V0.25P