F71862
Temperature 3 reading. The unit of reading is 1ºC.At the moment of reading this
76h
RO
--
register.
77-7Bh
7C-7Fh
RO
RO
--
FFh
Reserved
Reserved
80h
Reserved
FFh
Reserved
81h
82h
83h
84h
85h
86h
87h
88-8Bh
Reserved
FFh
Reserved
R/W
R/W
R/W
R/W
R/W
R/W
RO
64h
55h
64h
55h
55h
46h
--
Temperature sensor 1 OVT limit. The unit is 1ºC.
Temperature sensor 1 high limit. The unit is 1ºC.
Temperature sensor 2 OVT limit. The unit is 1ºC.
Temperature sensor 2 high limit. The unit is 1ºC.
Temperature sensor 3 OVT limit. The unit is 1ºC.
Temperature sensor 3 high limit. The unit is 1ºC.
Reserved
8C~8Dh
RO
FFH
Reserved
Temperature Filter Select Register -- Index 8Eh
Bit
Name
R/W Default
Description
The queue time for second filter to quickly update values.
00: disable.
7-6
IIR-QUEUR3
R/W
R/W
0h
0h
01: 16 times.
10: 32 times. (default)
11: 48 times.
The queue time for second filter to quickly update values.
00: disable.
01: 16 times.
10: 32 times. (default)
11: 48 times.
5-4
IIR-QUEUR2
The queue time for second filter to quickly update values.
00: disable.
01: 16 times.
10: 32 times. (default)
11: 48 times.
--
3-2
0
IIR-QUEUR1
Reserved
R/W
R
0h
0h
Fan Control Setting
FAN PME# Enable Register Index 90h
Bit Name R/W Default
7-3 Reserved
Description
Reserved
RO
R/W
0h
0h
EN_FAN3_PME
A one enables the corresponding interrupt status bit for PME# interrupt..
Set this bit 1 to enable PME# function for Fan3.
A one enables the corresponding interrupt status bit for PME# interrupt.
Set this bit 1 to enable PME# function for Fan2.
A one enables the corresponding interrupt status bit for PME# interrupt.
Set this bit 1 to enable PME# function for Fan1.
2
1
0
0h
0h
EN_FAN2_PME
EN_FAN1_PME
R/W
R/W
FAN Interrupt Status Register Index 91h
Bit Name R/W Default
7-3 Reserved
Description
Reserved
RO
0
55
July, 2008
V.28P