欢迎访问ic37.com |
会员登录 免费注册
发布采购

FTLX3611M340 参数 Datasheet PDF下载

FTLX3611M340图片预览
型号: FTLX3611M340
PDF下载: 下载PDF文件 查看货源
内容描述: 符合RoHS-6的10Gb / s DWDM 40公里多速率XFP光收发器 [RoHS-6 Compliant 10Gb/s DWDM 40km Multi-Rate XFP Optical Transceiver]
分类和应用: 光纤通信
文件页数/大小: 13 页 / 293 K
品牌: FINISAR [ FINISAR CORPORATION. ]
 浏览型号FTLX3611M340的Datasheet PDF文件第1页浏览型号FTLX3611M340的Datasheet PDF文件第2页浏览型号FTLX3611M340的Datasheet PDF文件第3页浏览型号FTLX3611M340的Datasheet PDF文件第4页浏览型号FTLX3611M340的Datasheet PDF文件第6页浏览型号FTLX3611M340的Datasheet PDF文件第7页浏览型号FTLX3611M340的Datasheet PDF文件第8页浏览型号FTLX3611M340的Datasheet PDF文件第9页  
FTLX3611M3 DWDM XFP Product Specification – February 2008  
F i n i s a r  
III.  
Electrical Characteristics (TOP = -5 to 70 °C, VCC5 = 4.75 to 5.25 Volts)  
Parameter  
Main Supply Voltage  
Supply Voltage #2  
Supply Voltage #3  
Supply Current – Vcc5 supply  
Supply Current – Vcc3 supply  
Supply Current – Vcc2 supply  
Module total power  
Symbol  
Vcc5  
Vcc3  
Vcc2  
Icc5  
Icc3  
Icc2  
P
Min  
4.75  
3.13  
1.71  
Typ  
Max  
5.25  
3.45  
1.89  
350  
400  
750  
3.5  
Unit  
V
V
Ref.  
V
mA  
mA  
mA  
W
1
Transmitter  
Input differential impedance  
Differential data input swing  
Transmit Disable Voltage  
Transmit Enable Voltage  
Transmit Disable Assert Time  
Receiver  
Differential data output swing  
Data output rise time  
Data output fall time  
LOS Fault  
LOS Normal  
Power Supply Rejection  
Reference Clock  
Rin  
Vin,pp  
VD  
100  
650  
2
3
Ω
mV  
V
V
us  
120  
2.0  
GND  
820  
Vcc  
GND+ 0.8  
10  
VEN  
Vout,pp  
tr  
340  
850  
38  
38  
mV  
ps  
ps  
V
4
5
5
6
6
7
tf  
VLOS fault  
VLOS norm  
PSR  
Vcc – 0.5  
GND  
VccHOST  
GND+0.5  
V
See Note 6 below  
Clock differential input impedance  
Reference Clock frequency  
Differential clock input swing  
Clock output rise/fall time  
Reference clock frequency tolerance  
Rclkin  
100  
Baud/64  
1600  
Ω
f0  
Vclkin,pp  
trf  
MHz  
mV  
ps  
640  
200  
-100  
1250  
+100  
5
Df  
PPM  
Notes:  
1. Maximum total power value is specified across the full temperature and voltage range.  
2. After internal AC coupling.  
3. Or open circuit.  
4. Into 100 ohms differential termination.  
5. 20 – 80 %  
6. Loss Of Signal is open collector to be pulled up with a 4.7k – 10kohm resistor to 3.15 – 3.6V. Logic 0  
indicates normal operation; logic 1 indicates no signal detected.  
7. Per Section 2.7.1. in the XFP MSA Specification1.  
© Finisar Corporation 7-February-2008  
Rev B2  
Page 5  
 复制成功!