FTLX3611M3 DWDM XFP Product Specification – February 2008
F i n i s a r
III.
Electrical Characteristics (TOP = -5 to 70 °C, VCC5 = 4.75 to 5.25 Volts)
Parameter
Main Supply Voltage
Supply Voltage #2
Supply Voltage #3
Supply Current – Vcc5 supply
Supply Current – Vcc3 supply
Supply Current – Vcc2 supply
Module total power
Symbol
Vcc5
Vcc3
Vcc2
Icc5
Icc3
Icc2
P
Min
4.75
3.13
1.71
Typ
Max
5.25
3.45
1.89
350
400
750
3.5
Unit
V
V
Ref.
V
mA
mA
mA
W
1
Transmitter
Input differential impedance
Differential data input swing
Transmit Disable Voltage
Transmit Enable Voltage
Transmit Disable Assert Time
Receiver
Differential data output swing
Data output rise time
Data output fall time
LOS Fault
LOS Normal
Power Supply Rejection
Reference Clock
Rin
Vin,pp
VD
100
650
2
3
Ω
mV
V
V
us
120
2.0
GND
820
Vcc
GND+ 0.8
10
VEN
Vout,pp
tr
340
850
38
38
mV
ps
ps
V
4
5
5
6
6
7
tf
VLOS fault
VLOS norm
PSR
Vcc – 0.5
GND
VccHOST
GND+0.5
V
See Note 6 below
Clock differential input impedance
Reference Clock frequency
Differential clock input swing
Clock output rise/fall time
Reference clock frequency tolerance
Rclkin
100
Baud/64
1600
Ω
f0
Vclkin,pp
trf
MHz
mV
ps
640
200
-100
1250
+100
5
Df
PPM
Notes:
1. Maximum total power value is specified across the full temperature and voltage range.
2. After internal AC coupling.
3. Or open circuit.
4. Into 100 ohms differential termination.
5. 20 – 80 %
6. Loss Of Signal is open collector to be pulled up with a 4.7k – 10kohm resistor to 3.15 – 3.6V. Logic 0
indicates normal operation; logic 1 indicates no signal detected.
7. Per Section 2.7.1. in the XFP MSA Specification1.
© Finisar Corporation 7-February-2008
Rev B2
Page 5