FTLX3815M3xx DWDM XFP Product Specification Nov 2014  
F i n i s a r  
III.  
Electrical Characteristics (TOP = -5 to 70 C, VCC5 = 4.75 to 5.25 Volts)  
FTLX3815M3xx  
Parameter  
Supply Voltage #1  
Supply Voltage #2  
Symbol  
Vcc3  
Vcc5  
Icc5  
Icc3  
P
Min  
3.13  
4.75  
Typ  
Max  
3.46  
5.25  
450  
750  
3.5  
Unit  
V
V
mA  
mA  
W
  
mV  
V
Ref.  
Supply Current Vcc5 supply  
Supply Current Vcc3 supply  
Module total power dissipation  
Transmitter  
Input differential impedance  
Differential data input swing  
Transmit Disable Voltage  
Transmit Enable Voltage  
Receiver  
Differential data output swing  
Data output rise time  
Data output fall time  
LOS Fault  
1
Rin  
Vin,pp  
VD  
100  
500  
2
3
120  
2.0  
GND  
820  
Vcc  
GND+ 0.8  
VEN  
V
mV  
ps  
ps  
V
Vout,pp  
tr  
850  
40  
40  
4
5
5
6
6
7
tf  
VLOS fault  
VLOS norm  
PSR  
Vcc 0.5  
GND  
VccHOST  
GND+0.5  
LOS Normal  
V
Power Supply Rejection  
Reference Clock (AC-Coupled)  
Single-ended peak to peak voltage  
swing  
See Note 7 below  
VSEPP  
200  
450  
mV  
Single-ended resistance  
Frequency clock tolerance  
Duty cycle  
RL  
Δf  
-
40  
-100  
40  
50  
60  
+100  
60  
ppm  
%
Notes:  
1. Maximum total power value is specified across the full temperature and voltage range.  
2. After internal AC coupling.  
3. Or open circuit.  
4. Into 100 ohms differential termination.  
5. 20 80 %  
6. Loss Of Signal is open collector to be pulled up with a 4.7k 10kohm resistor to 3.15 3.6V. Logic 0  
indicates normal operation; logic 1 indicates no signal detected.  
7. Per Section 2.7.1. in the XFP MSA Specification1.  
Rev.: A04  
Page 4 of 23  
1174161  
This document contains proprietary and confidential information to Finisar Corp. This document and the entire information  
contained herein, and any other tangible representation thereof, is not to be copied, reproduced, duplicated, distributed, or  
modified, in whole or in part, and/or used without the expressed written consent of Finisar Corp.  
Printed copy may not be the latest revision please refer to Agile for current revision  