欢迎访问ic37.com |
会员登录 免费注册
发布采购

FTLX1841E2 参数 Datasheet PDF下载

FTLX1841E2图片预览
型号: FTLX1841E2
PDF下载: 下载PDF文件 查看货源
内容描述: 符合RoHS-6的10Gb / s 1550nm的单模数据通信X2 ZR转发 [RoHS-6 Compliant 10Gb/s 1550nm Single Mode Datacom X2 ZR Transponder]
分类和应用: 数据通信
文件页数/大小: 10 页 / 236 K
品牌: FINISAR [ FINISAR CORPORATION. ]
 浏览型号FTLX1841E2的Datasheet PDF文件第2页浏览型号FTLX1841E2的Datasheet PDF文件第3页浏览型号FTLX1841E2的Datasheet PDF文件第4页浏览型号FTLX1841E2的Datasheet PDF文件第5页浏览型号FTLX1841E2的Datasheet PDF文件第6页浏览型号FTLX1841E2的Datasheet PDF文件第7页浏览型号FTLX1841E2的Datasheet PDF文件第9页浏览型号FTLX1841E2的Datasheet PDF文件第10页  
FTLX1841 Product Specification – August 2008
Environmental Performance
Operating case temperature:
Operating humidity:
Fibers and Connectors
The transponder has SC receptacles for both Tx and Rx. The transponder is designed for
single mode SC cables, 0° polished endface (PC).
70-pin Connector
The module interface connector is a 70-pin, printed circuit board edge connection with a
0.5 mm pitch. The appropriate mating connector for the customer PCB is a 70-pin SMT,
dual row, right angled, edge connector, 0.5 mm pitch (Tyco Electronics part number
1367337-1, Molex part number 74441-0003 or equivalent).
Rail and Mechanical Mounting Requirements
The X2 rail system required to mount the X2 module is fully defined by the MSA.
(Tyco Electronics part number 1367608-1: designed for belly to belly applications;
and 1367610-1, designed for single sided board mount to fit into the standard host PCB
footprint; or equivalent). For further details please refer to vendor-supplied information.
Aqueous Wash
Finisar X2 transponders are neither solderable nor aqueous washable and are not
intended for these processes.
0°C to +70°C
0% -95% RH non-condensing
VI. Regulatory Compliance
Feature
ESD:
Electrostatic Discharge to the
Electrical Pins (HBM)
Immunity:
Against Electrostatic Discharge
(ESD) to the Module Receptacle
Immunity:
Against Radio Frequency
Electromagnetic Field
Emission:
Electromagnetic Interference
(EMI)
Standard
EIA/JESD22-A114-B
(MIL-STD 883D
Method 3015.7)
EN 61000-4-2
IEC 61000-4-2
Comments
Class 1a (> 500 V)
Discharges ranging from
±
2 kV to
±
25 kV to
the front end / faceplate / receptacle cause no
damage to module (under recommended
conditions).
With a field strength of 10 V/m, noise
frequency ranges from 10 MHz to 2 GHz. No
effect on module performance between the
specification limits.
Noise frequency range:
30 MHz to 40 GHz
Radiated emission does not exceed specified
limits when measured with module inside a
shielding enclosure with a MSA conforming
cutout.
EN 61000-4-3
IEC 61000-4-3
FCC 47 CFR
Part 15, Class B
EN 55022 Class B
CISPR 22
©
Finisar Corporation – August 2008 Rev. D1
Page 8