FTLF8519F2KNL 参数 Datasheet PDF下载

FTLF8519F2KNL图片预览
型号: FTLF8519F2KNL
PDF下载: 下载PDF文件 查看货源
内容描述: 2.125 Gb / s的符合RoHS短波长2× SFF收发器 [2.125 Gb/s RoHS Compliant Short Wavelength 2x5 SFF Transceiver]
分类和应用: 光纤通信
文件页数/大小: 10 页 / 230 K
品牌: FINISAR [ FINISAR CORPORATION. ]
 浏览型号FTLF8519F2KNL的Datasheet PDF文件第1页浏览型号FTLF8519F2KNL的Datasheet PDF文件第2页浏览型号FTLF8519F2KNL的Datasheet PDF文件第3页浏览型号FTLF8519F2KNL的Datasheet PDF文件第5页浏览型号FTLF8519F2KNL的Datasheet PDF文件第6页浏览型号FTLF8519F2KNL的Datasheet PDF文件第7页浏览型号FTLF8519F2KNL的Datasheet PDF文件第8页浏览型号FTLF8519F2KNL的Datasheet PDF文件第9页  
FTLF8519F2xNL 2x5 Pin SFF Product Specification – December 2005
IV.
Optical Characteristics
(T
OP
= -10 to 85
°C,
V
CC
= 3.0 to 3.6 Volts)
Parameter
Symbol
P
OUT
λ
σ
OMA
Tx
t
r
/ t
f
RIN
TX
Δ
DJ
TX
Δ
TJ
ER
Min
-9
830
196
150
-120
56.5
119
Typ
Max
-3
860
0.85
Unit
dBm
nm
nm
μW
ps
dB/Hz
ps
ps
dB
Ref.
1
Transmitter
Output Opt. Pwr: 50 or 62.5 MMF
Optical Wavelength
Spectral Width
Optical Modulation Amplitude
Optical Rise/Fall Time
Relative Intensity Noise
Deterministic Jitter Contribution (p-p)
Total Jitter Contribution (p-p)
Extinction Ratio @ 1.25 Gb/s
Mask Margin
Receiver
Receiver Sensitivity = 1.0625 Gb/s
Receiver Sensitivity = 2.125 Gb/s
Receiver Sensitivity = 1.25 Gb/s
Stressed RX sens. = 1.0625 Gb/s
Stressed RX sens. = 2.125 Gb/s
Stressed RX sens = 1.25 Gb/s
Average Received Power
Receiver Elec. 3 dB cutoff freq.
Optical Center Wavelength
Return Loss
Signal Detect Normal
Signal Detect Fault
Signal Detect Hysteresis
2
3
4
5
20
9
45%
Rx
SENS
Rx
SENS
Rx
SENS
0.055
0.096
Rx
MAX
λ
C
RL
SD
normal
SD
fault
770
12
-30
0.5
-20
-18
-20
-13.5
0
1500
860
-20
dBm
dBm
dBm
mW
mW
dBm
dBm
MHz
nm
dB
dBm
dBm
dB
6
6
7
8
8
9
Notes:
1. Class 1 Laser Safety per FDA/CDRH, EN (IEC) 60825 laser safety regulations.
2. Equivalent extinction ratio specification for Fibre Channel. Allows smaller ER at higher average
power.
3. Unfiltered, 20-80%. Complies with FC 1x and 2x eye mask when filtered.
4. Measured with DJ-free data input signal. In actual application, output DJ will be the sum of input DJ
and
Δ
DJ.
5. If measured with TJ-free data input signal. In actual application, output TJ will be given by:
TJ
OUT
=
DJ
IN
+ Δ
DJ
+
6.
7.
8.
9.
(
TJ
IN
DJ
IN
)
2
+
(
Δ
TJ
− Δ
DJ
)
2
Specifications are for 50 micro-meter or 62.5 micro-meter fiber
As measured with 9dB extinction ratio.
Measured with conformance signals defined in FC-PI-2 10.0 specifications.
Measured with conformance signals defined in IEEE 802.3 specifications.
©