欢迎访问ic37.com |
会员登录 免费注册
发布采购

FTLF1621S1MCL 参数 Datasheet PDF下载

FTLF1621S1MCL图片预览
型号: FTLF1621S1MCL
PDF下载: 下载PDF文件 查看货源
内容描述: OC- 48 LR - 2 / STM L- 16.2多速率2× SFF收发器 [OC-48 LR-2/STM L-16.2 Multirate 2x10 SFF Transceiver]
分类和应用: 光纤局域网通信
文件页数/大小: 12 页 / 213 K
品牌: FINISAR [ FINISAR CORPORATION. ]
 浏览型号FTLF1621S1MCL的Datasheet PDF文件第1页浏览型号FTLF1621S1MCL的Datasheet PDF文件第2页浏览型号FTLF1621S1MCL的Datasheet PDF文件第3页浏览型号FTLF1621S1MCL的Datasheet PDF文件第4页浏览型号FTLF1621S1MCL的Datasheet PDF文件第6页浏览型号FTLF1621S1MCL的Datasheet PDF文件第7页浏览型号FTLF1621S1MCL的Datasheet PDF文件第8页浏览型号FTLF1621S1MCL的Datasheet PDF文件第9页  
FTLF1621S1xCL 2x10 Pin SFF Product Specification – November 2005
Finisar
V.
General Specifications
Parameter
Symbol
BR
BER
L
MAX1
L
MAX2
L
MAX3
L
MAX4
L
MAX5
Min
155
Typ
Max
2667
10
-12
Units
Mb/s
km
km
km
km
km
Notes
1
2
3
3
3
3
3
Data Rate
Bit Error Rate
Max. Supported Link Length on
9/125µm SMF @ OC-48
Max. Supported Link Length on
9/125µm SMF @ 2X Fibre Channel
Max. Supported Link Length on
9/125µm SMF @ Gigabit Ethernet
Max. Supported Link Length on
9/125µm SMF @ OC-12
Max. Supported Link Length on
9/125µm SMF @ OC-3
80
85
100
100
100
Notes:
1. SONET OC-48 LR-2/SDH STM L-16.2 compliant. Compatible with Gigabit Ethernet, 1X/2X Fibre
Channel, SONET OC-12 and OC-3. Supports FEC at 2.67Gb/s.
2. Tested with a PRBS 2
31
-1 test pattern interspersed with 72 consecutive ones and 72 consecutive zeros
unless otherwise specified.
3. Attenuation of 0.275 dB/km is used for the link length calculations (per GR-253 CORE). A 2dB
penalty is included for dispersion on >2Gb/s data rates. Distances are indicative only. Please refer to
the Optical Specifications in Table IV to calculate a more accurate link budget based on specific
conditions in your application.
VI.
Environmental Specifications
Symbol
T
op
T
sto
Min
-10
-40
Typ
Max
70
85
Units
°C
°C
Parameter
Case Operating Temperature
Storage Temperature
VII.
Regulatory Compliance
Finisar transceivers are Class 1 Laser Products and comply with US FDA regulations.
These products are certified by TÜV and CSA to meet the Class 1 eye safety
requirements of EN (IEC) 60825 and the electrical safety requirements of
EN (IEC) 60950. Copies of certificates are available at Finisar Corporation upon request.
©
Finisar Corporation March 2006 Rev A
Page 5