FTLF1318P2xTL SFP Product Specification – April 2007
Finisar
V.
General Specifications
Parameter
Symbol
BR
BER
L
MAX1
L
MAX2
Min
1062
Typ
Max
1250
10
-12
Units
Ref.
Mb/sec 1
2
km
3, 4
km
3, 4
Data Rate
Bit Error Rate
Max. Supported Link Length on
9/125μm SMF @ 1X Fibre Channel
Max. Supported Link Length on
9/125μm SMF @ Gigabit Ethernet
10
10
Notes:
1. Gigabit Ethernet and 1x Fibre Channel compliant.
2. Tested with a PRBS 2
7
-1 test pattern.
3. Dispersion limited per FC-PI-2 Rev. 10
4. Attenuation of 0.55 dB/km is used for the link length calculations. Distances are indicative only.
Please refer to the Optical Specifications in Table IV to calculate a more accurate link budget based on
specific conditions in your application.
VI.
Environmental Specifications
Finisar 1310nm Industrial Temperature SFP transceivers have an operating temperature
range from -40°C to +85°C case temperature.
Parameter
Case Operating Temperature
Storage Temperature
Symbol
T
op
T
sto
Min
-40
-40
Typ
Max
85
100
Units
°C
°C
Ref.
VII.
Regulatory Compliance
Finisar transceivers are Class 1 Laser Products and comply with US FDA regulations.
These products are certified by TÜV and CSA to meet the Class 1 eye safety
requirements of EN (IEC) 60825 and the electrical safety requirements of EN (IEC)
60950. Copies of certificates are available at Finisar Corporation upon request.
©
Finisar Corporation April 12, 2007 Rev. A1
Page 5