FTLF1217P2xTL Pluggable SFP Product Specification – September 2008
II.
Absolute Maximum Ratings
Parameter
Maximum Supply Voltage
Storage Temperature
Case Operating Temperature
Relative Humidity
Symbol
Vcc
T
S
T
A
RH
Min
-0.5
-40
-40
0
Typ
Max
4.0
85
85
85
Unit
V
°C
°C
%
Ref.
1
III.
Electrical Characteristics
(T
A
= -40 to 85
°C,
V
CC
= 3.0 to 3.6 Volts)
Symbol
Vcc
Icc
R
in
Vin,pp
V
D
V
EN
Vout,pp
t
r
/t
f
V
LOS fault
V
LOS norm
PSR
RX
Δ
SJ
RX
Δ
DCD
RX
Δ
DDJ
RX
Δ
RJ
RX
Δ
RJ
Min
3.0
Typ
Max
3.6
300
Unit
V
mA
Ω
mV
V
V
mV
ns
V
V
mVpp
ns
ns
ns
ns
ns
Ref.
Parameter
Supply Voltage
Supply Current
Transmitter
Input differential impedance
Single ended data input swing
Transmit Disable Voltage
Transmit Enable Voltage
Receiver
Single ended data output swing
Data output rise/fall time
≤
155 Mb/s
LOS Fault
LOS Normal
Power Supply Rejection
Systematic Jitter Contribution
Contributed Duty Cycle Distortion
Data Dependent Jitter Contribution
Random Jitter Contribution @ OC-3
and OC-1
Random Jitter Contribution @ FE
100
250
2
Vee
250
0.6
2
Vee
100
450
1200
Vcc
Vee+ 0.8
900
5.0
Vcc
HOST
Vee+0.5
2.0
1.0
1.2
0.6
0.76
2
3
4
5
6
7
7
8
9
10
10
9
10
Notes:
1. Non condensing.
2. Connected directly to TX data input pins. AC coupling from pins into driver IC.
3. We recommend <600mV for best EMI performance.
4. Or open circuit.
5. Into 100 ohms differential termination.
6. 10 – 90 %
7. LOS is an open collector output. Should be pulled up with 4.7k – 10kohms on the host board. Normal
operation is logic 0; loss of signal is logic 1. Maximum pull-up voltage is 5.5V.
8. Receiver sensitivity is compliant with power supply sinusoidal modulation of 20 Hz to 1.5 MHz up to
specified value applied through the recommended power supply filtering network.
9. Peak-to-peak measurement for OC-3 SR-0 or OC-1 SR-0 operation measured with a PRBS 2
23
-1 test
pattern.
3
10. Peak-to-peak measurement based on 4B/5B encoded Fast Ethernet pattern referenced in FDDI PMD
Annex A.5
©
Finisar Corporation September 13, 2008 Rev. B
Page 4