FTL-1619-XX WDM GBIC
Product Specification February 2007
Finisar
II.
Electrical Power Interface
The GBIC specification calls for a range of 4.75V to 5.25 volts as described in Table 2.
The maximum voltage of 6V is not to be applied continuously.
Parameter
Supply Current
Maximum Voltage
Surge Current
Input Voltage
Power Supply Rejection
Symbol
I
s
V
max
I
surge
V
cc
PSR
4.75
100
5.00
Min
Typ
280
Max
350
6
400
5.25
Units
mA
V
mA
V
mV
Referenced to GND
See Note 1. Peak to Peak
Notes/Conditions
Table 2. Electrical power interface
Note 1:
Receiver sensitivity is compliant with power supply sinusoidal modulation of 20 Hz to 1.5 MHz up to
specified value applied through the recommended power supply filtering network.
III. Low Speed Signals
RX_LOS, TX_DISABLE, and TX_FAULT are TTL signals as described in Table 3.
MOD_DEF(1) (SCL) and MOD_DEF(2) (SDA) are open drain CMOS signals (see
section VIII, “Serial Communication Protocol”). Both MOD_DEF(1) and MOD_DEF(2)
must be pulled up to host Vcc. For more detailed information, see sections 5.3.1 – 5.3.8 in
the GBIC Specification Revision 5.5
3
.
Parameter
GBIC Output LOW
GBIC Output HIGH
GBIC Input LOW
Symbol
V
OL
Units Notes/Conditions
V
4.7k to 10k pull-up to host_Vcc,
measured at host side of connector
V
OH
host_Vcc - host_Vcc +
V
4.7k to 10k pull-up to host_Vcc,
0.5
0.3
measured at host side of connector
V
IL
0
0.8
V
4.7k to 10k pull-up to Vcc,
measured at GBIC side of
connector
V
IH
2
Vcc + 0.3
V
4.7k to 10k pull-up to Vcc,
measured at GBIC side of
connector
Table 3. Low speed signals – electronic characteristics
Min
0
Max
0.5
GBIC Input HIGH
© Finisar Corporation February 2007 – Rev. B
Page 3