PRELIMINARY DATA SHEET
FP4050
2-W
ATT
P
OWER
PHEMT
•
RECOMMENDED CONTINUOUS OPERATING LIMITS
Parameter
Drain-Source Voltage
Gate-Source Voltage
Drain-Source Current
RF Input Power
Channel Operating Temperature
Ambient Temperature
Symbol
V
DS
V
GS
I
DS
P
IN
T
CH
T
STG
Nominal
8
-1.0
500
800
150
-20/50
Units
V
V
mA
mW
°C
°C
Note:
Device should be operated at or below Recommended Continuous Operating Limits for reliable performance.
•
ABSOLUTE RATINGS
Parameter
Drain-Source Voltage
Gate-Source Voltage
Drain-Source Current
Gate Current
RF Input Power
Channel Operating Temperature
Storage Temperature
device.
Symbol
V
DS
V
GS
I
DS
I
G
P
IN
T
CH
T
STG
Test Conditions
T
Ambient
= 22
±
3
°C
T
Ambient
= 22
±
3
°C
T
Ambient
= 22
±
3
°C
T
Ambient
= 22
±
3
°C
T
Ambient
= 22
±
3
°C
T
Ambient
= 22
±
3
°C
—
Min
Max
10
-5
800
180
TBD
175
Units
V
V
mA
mA
mW
ºC
ºC
-65
175
Note:
Even temporary operating conditions that exceed the Absolute Maximum Ratings could result in permanent damage to the
•
HANDLING PRECAUTIONS
To avoid damage to the devices care should be exercised during handling. Proper Electrostatic
Discharge (ESD) precautions should be observed at all stages of storage, handling, assembly, and
testing. These devices should be treated as Class 1A (0-500 V). Further information on ESD control
measures can be found in MIL-STD-1686 and MIL-HDBK-263.
All information and specifications are subject to change without notice.
Phone:
(408) 988-1845
Fax:
(408) 970-9950
http://
www.filtronicsolidstate.com
Revised:
10/04/00