FMA246
Preliminary Datasheet v3.0
R
ECOMMENDED
A
SSEMBLY
S
CHEMATIC
:
Note:
1
The supply de-coupling capacitor (150 pF recommended value) should be placed as close to the MMIC as
practical.
2
The configuration shown below will result in operating current bias levels of approximately (for each stage) 50% /
50% / 75%, which is the standard recommended bias setting for the MMIC. For lower current operation, the 3
rd
stage can be set to 50% by bonding to the pad just to the left of the pad that is bonded in the drawing below
(marked “3”), in the right-most set of three bias pads. These number markings are the resistor values (Ohms)
between the pads.
4
Tel: +44 (0) 1325 301111
Preliminary specifications subject to change without notice
Filtronic Compound Semiconductors Ltd
Fax: +44 (0) 1325 306177
Email: sales@filcs.com
Website:
www.filtronic.com