AC Electrical Characteristics
VCC
T
A = +25°C
TA = −40°C to +85°C
Symbol
Parameter
Units Conditions Fig. No.
(V)
1.8
Min
2.0
0.8
0.5
0.5
1.5
0.8
Typ
4.4
2.9
2.1
1.8
2.9
2.4
4
Max
9.5
6.5
4.5
3.9
5.0
4.3
Min
2.0
0.8
0.5
0.5
1.5
0.8
Max
10
tPLH
tPHL
Propagation Delay
2.5 ± 0.2
3.3 ± 0.3
5.0 ± 0.5
3.3 ± 0.3
5.0 ± 0.5
0
7.0
4.7
4.1
5.2
4.5
C
R
L = 15 pF
L = 1 MΩ
Figures
1, 3
ns
tPLH
tPHL
CIN
Propagation Delay
C
L = 50 pF
L = 500Ω
Figures
1, 3
ns
pF
pF
R
Input Capacitance
CPD
Power Dissipation Capacitance
3.3
20
(Note 3)
Figure 2
5.0
26
Note 3: CPD is defined as the value of the internal equivalent capacitance which is derived from dynamic operating current consumption (ICCD) at no output
loading and operating at 50% duty cycle. (See Figure 2.) CPD is related to ICCD dynamic operating current by the expression:
ICCD = (CPD) (VCC) (fIN) + (ICC static)
AC Loading and Waveforms
CL includes load and stray capacitance
Input PRR = 1.0 MHz, tW = 500 ns
FIGURE 1. AC Test Circuit
FIGURE 3. AC Waveforms
Input = AC Waveform; tr = tf = 1.8 ns;
PRR = 10 MHz; Duty Cycle = 50%
FIGURE 2. ICCD Test Circuit
3
www.fairchildsemi.com