74VHC32
AC Electrical Characteristics
Symbol
t
PHL
t
PLH
Parameter
Propagation Delay
V
CC
(V)
3.3
±0.3
5.0
±0.5
C
IN
C
PD
Input Capacitance
Power Dissipation
Capacitance
Note 4:
C
PD
is defined as the value of the internal equivalent capacitance which is calculated from the operating current consumption without load. Average
operating current can be obtained by the equation: I
CC
(opr.)
=
C
PD
* V
CC
* f
IN
+
I
CC
/4 (per gate).
T
A
=
25°C
Min
Typ
5.5
8.0
3.8
5.3
4
14
Max
7.9
11.4
5.5
7.5
10
T
A
= −40°C
to
+85°C
Min
1.0
1.0
1.0
1.0
Max
9.5
13.0
6.5
8.5
10
Units
ns
ns
pF
pF
Conditions
C
L
=
15 pF
C
L
=
50 pF
C
L
=
15 pF
C
L
=
50 pF
V
CC
=
Open
(Note 4)
3