DC Electrical Characteristics
Symbol
I
CC
Parameter
Quiescent Supply Current
Increase in I
CC
per Input
V
I
V
IH
(Continued)
V
CC
(V)
2.3 to 3.6
2.3 to 3.6
2.3 to 3.6
T
A
Min
Conditions
V
CC
or GND
V
CC
0.6V
40
q
C to
85
q
C
Max
10
Units
3.6V
d
V
I
, V
O
d
5.5V (Note 9)
r
10
500
P
A
P
A
'
I
CC
Note 9:
Outputs disabled or 3-STATE only.
AC Electrical Characteristics
T
A
Symbol
Parameter
V
CC
C
L
Min
t
PHL
t
PLH
t
PZL
t
PZH
t
PLZ
t
PHZ
t
OSHL
t
OSLH
Output to Output Skew
(Note 10)
Output Disable Time
Propagation Delay
A
n
to B
n
or B
n
to A
n
Output Enable Time
1.5
1.5
1.5
1.5
1.5
1.5
3.3V
r
0.3V
50 pF
Max
7.0
7.0
8.5
8.5
7.5
7.5
1.0
1.0
Min
1.5
1.5
1.5
1.5
1.5
1.5
40
q
C to
85
q
C, R
L
V
CC
C
L
2.7V
50 pF
Max
8.0
8.0
9.5
9.5
8.5
8.5
500
:
V
CC
C
L
Min
1.5
1.5
1.5
1.5
1.5
1.5
2.5V
r
0.2V
30 pF
Max
8.4
8.4
10.5
10.5
9.0
9.0
ns
ns
ns
ns
Units
Note 10:
Skew is defined as the absolute value of the difference between the actual propagation delay for any two separate outputs of the same device. The
specification applies to any outputs switching in the same direction, either HIGH-to-LOW (t
OSHL
) or LOW-to-HIGH (t
OSLH
).
Dynamic Switching Characteristics
Symbol
V
OLP
V
OLV
Parameter
Quiet Output Dynamic Peak V
OL
Quiet Output Dynamic Valley V
OL
C
L
C
L
C
L
C
L
50 pF, V
IH
30 pF, V
IH
50 pF, V
IH
30 pF, V
IH
Conditions
3.3V, V
IL
2.5V, V
IL
3.3V, V
IL
2.5V, V
IL
0V
0V
0V
0V
V
CC
(V)
3.3
2.5
3.3
2.5
T
A
25
q
C
0.8
0.6
Typical
Units
V
V
0.8
0.6
Capacitance
Symbol
C
IN
C
I/O
C
PD
Parameter
Input Capacitance
Input/Output Capacitance
Power Dissipation Capacitance
V
CC
V
CC
V
CC
Open, V
I
3.3V, V
I
3.3V, V
I
Conditions
0V or V
CC
0V or V
CC
0V or V
CC
, f
10 MHz
Typical
7.0
8.0
25.0
Units
pF