74AC04, 74ACT04 Hex Inverter
DC Electrical Characteristics for ACT
Symbol
V
IH
V
IL
V
OH
Parameter
Minimum HIGH Level
Input Voltage
Maximum LOW Level
Input Voltage
Minimum HIGH Level
Output Voltage
V
CC
(V)
4.5
5.5
4.5
5.5
4.5
5.5
T
A
=
+25°C
Conditions
V
OUT
=
0.1V or
V
CC
– 0.1V
V
OUT
=
0.1V or
V
CC
– 0.1V
I
OUT
=
–50µA
V
IN
=
V
IL
or V
IH
:
T
A
=
–40°C to +85°C
Guaranteed Limits
Units
V
V
V
2.0
2.0
0.8
0.8
4.4
5.4
3.76
4.76
0.1
0.1
0.44
0.44
±1.0
1.5
75
–75
µA
mA
mA
mA
µA
V
Typ.
1.5
1.5
1.5
1.5
4.49
5.49
2.0
2.0
0.8
0.8
4.4
5.4
3.86
4.86
0.001
0.001
0.1
0.1
0.36
0.36
±0.1
0.6
4.5
5.5
V
OL
Maximum LOW Level
Output Voltage
4.5
5.5
I
OH
=
–24mA
I
OH
=
–24mA
(4)
I
OUT
=
50µA
V
IN
=
V
IL
or V
IH
:
4.5
5.5
I
IN
I
CCT
I
OLD
I
OHD
I
CC
Maximum Input
Leakage Current
Maximum I
CC
/Input
Minimum Dynamic
Output Current
(5)
Maximum Quiescent
Supply Current
5.5
5.5
5.5
5.5
5.5
I
OL
=
24mA
I
OL
=
24mA
(4)
V
I
=
V
CC
, GND
V
I
=
V
CC
– 2.1V
V
OLD
=
1.65V Max.
V
OHD
=
3.85V Min.
V
IN
=
V
CC
or GND
4.0
40.0
Notes:
4. All outputs loaded; thresholds on input associated with output under test.
5. Maximum test duration 2.0ms, one output loaded at a time.
©2005 Fairchild Semiconductor Corporation
74AC04, 74ACT04 Rev. 1.0
www.fairchildsemi.com
4