ELECTRICAL CHARACTERISTICS
PARAMETER MIN
TYP MAX UNITS
CONDITIONS
V1 =1.6V to 5.5V; TA = -40ºC to +85ºC; unless otherwise noted. Typical values are at TA =+25ºC
Operating Voltage
Range
0.9
5.5
30
25
V
T = -40ºC to +85ºC
A
V1 < 5.5V, V2 < 3.60V, all I/O
pins open
V1 < 3.6V, V2 < 2.75V, all I/O
pins open
20
15
uA
Supply Current
4.532
4.287
3.013
2.866
2.572
2.273
2.146
1.636
1.548
2.266
2.144
1.631
1.543
1.360
1.286
1.087
1.029
0.816
0.772
4.625
4.375
3.075
2.925
2.625
2.320
2.190
1.670
1.580
2.313
2.188
1.665
1.575
1.388
1.313
1.110
1.050
0.833
0.788
4.718
4.463
3.137
2.984
2.678
2.367
2.234
1.704
1.612
2.360
2.232
1.698
1.607
1.416
1.340
1.133
1.071
0.850
0.804
Z (valid for V1 falling)
Y (valid for V1 falling)
X (valid for V1 falling)
W (valid for V1 falling)
V (valid for V1 falling)
U (valid for V1 falling)
T (valid for V1 falling)
S (valid for V1 falling)
R (valid for V1 falling)
J (valid for V2 falling)
I (valid for V2 falling)
H (valid for V2 falling)
G (valid for V2 falling)
F (valid for V2 falling)
E (valid for V2 falling)
D (valid for V2 falling)
C (valid for V2 falling)
B (valid for V2 falling)
A (valid for V2 falling)
V1 Reset
Threshold
V
V2 Reset
Threshold
V
Threshold 1
Tempco
Threshold 2
Tempco
Threshold 1
Hysteresis
Threshold 2
Hysteresis
0.06
0.04
0.65
0.5
mV/ºC
mV/ºC
%
reference to Vth1 typical
reference to Vth2 typical
%
V1 to RST/RSTB
Delay
V1 = Vth1 to (Vth1-0.1V), Vth1
= 3.075
50
us
V2 to RST/RSTB
Delay
V2 = Vth2 to (Vth2-0.1V), Vth2
= 1.575
50
us
Reset Timeout
Period (T1)
Reset Timeout
Period (T2)
Reset Timeout
Period (T3)
Reset Timeout
Period (T4)
37
74
50
63
ms
TOPT-1
TOPT-2
TOPT-3
TOPT-4
100
200
400
126
252
504
ms
148
296
ms
ms
Nov20-06 Rev M
SP6330/32/34 Quad Power Supervisory Circuit Family
© Copyright 2006 Sipex Corporation