CLC2011, CLC4011
Absolute Maximum Ratings
Stresses beyond the limits listed below may cause
permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect
device reliability and lifetime.
V
S
..................................................................................... 0V to 6V
V
IN
............................................................ -V
S
- 0.5V to +V
S
+0.5V
Continuous Output Current ..................................-40mA to +40mA
Operating Conditions
Supply Voltage Range ...................................................2.5 to 5.5V
Operating Temperature Range ...............................-40°C to 125°C
Junction Temperature ........................................................... 150°C
Storage Temperature Range...................................-65°C to 150°C
Lead Temperature (Soldering, 10s) ......................................260°C
Package Thermal Resistance
θ
JA
(SOIC-8) .....................................................................150°C/W
θ
JA
(MSOP-8) .................................................................. 200°C/W
θ
JA
(SOIC-14) .................................................................... 90°C/W
θ
JA
(TSSOP-14) ................................................................100°C/W
Package thermal resistance (θ
JA
), JEDEC standard, multi-layer
test boards, still air.
ESD Protection
CLC2011, CLC4011 (HBM) .......................................................2kV
ESD Rating for HBM (Human Body Model).
© 2009 - 2014 Exar Corporation
2 / 17
Rev 1D